EasyManua.ls Logo

Yamato PPC-200W - III Directions for Use; Installing Batteries or AC adaptor; Leveling the Scale; Turning the Scale On and Off

Yamato PPC-200W
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
YCO-1047-07-04
PPC-200(W) Operation Manual
Remove everything from the platform surface and press the
key. The display will briefl y fl ash all the LCDs. After ap prox i-
mate ly 5 seconds, the display will stop fl ashing and au to mat i-
cal ly set to zero.
III Directions for Use
III.A Installing Batteries or AC adaptor
Remove the stainless steel platform. Gently and carefully turn the scale on it's side. Ensure the surface
around the battery cover is dry. Do not allow water to enter the battery compartment. Turn the bat-
tery cover thumb screw coun ter clock wise until it comes free. Swing the cover open. Install the bat-
ter ies ac cord ing to the po lar i ty mark ings. If you reverse the po lar i ties of the batteries, the scale will
be dam aged. Swing the battery cover into place and insert the thumb screw. Tighten the thumbsrew
securely. If the battery cover is loose, the washdown seal will leak.
Use only the AC adaptor specifi ed for use with the scale. Using the wrong adaptor can damage the
scale. Remove the battery cover and the batteries, if installed. Re place the bat tery cover. Remove
the washdown plug from the jack. Insert the adaptor plug securely into the jack. Do not washdown
the scale if an AC adaptor is in use or if the washdown plug has been removed from the AC jack.
III.B Leveling the Scale
Place the scale on a fl at and level surface. If the scale is not level, the read ings may
not be ac cu rate. You can check whether the scale is level by using the bub ble
level device po si tioned on the left front surface of the scale. Adjust the feet by turn-
ing them in or out to lower or raise the corner of the scale the foot is on.
III.C Turning the Scale On and Off
Press the key. The display will go off. Under battery op er a tion, the power will be shut off au to -
mat i cal ly (AutoOff function) after about 15 minutes of non-use, even if you don’t press the
key.
2
III.D Checking the Battery Level
Turn the scale on and push the key while the display is fl ash-
ing. The remaining battery life will be displayed. The more “o”
you see, the more life there is left in the batteries. After a few
seconds, the scale will go to weighing mode.
III.E Zero the Display
The scale will zero automatically when turned on. If a value is dis played when the plat form is empty,
push the
key to zero the display. The maximum zero range during power up is approximately
± 1.9% of the scale capacity.
III.F Switching Between LB and KG
To switch between LB and KG, press and hold the key and press the key.

Other manuals for Yamato PPC-200W

Related product manuals