5 Installation Procedure
YASKAWA ELECTRIC SIEP C730600 59A V1000 Option Modbus TCP/IP Technical Manual 15
Table 6 Ground Wire Selection
5. For IP20/Open-Chassis models, go to Step 9. on page 16.
6. For IP20/NEMA Type 1 enclosure models CIMR-VAF, loosen the screw on the front of the NEMA
Type 1 terminal cover and remove it from the drive. Refer to Figure 8 for details.
Refer to Figure 9 for drive models CIMR-VBA0006F to BA0018F, 2A0008F to 2A0069F, and 4A0001F to
4A0038F, which require removing the plastic terminal cover prior to removing the NEMA Type 1 terminal cover.
Note: Installing the option on an IP20/NEMA Type 1 enclosure drive voids NEMA Type 1 protection while maintaining IP20
conformity.
Figure 8
Figure 8 Remove the NEMA Type 1 Terminal Cover (CIMR-VBA0001F to BA0003F, 2A0001F to 2A0006F)
Figure 9
Figure 9 Remove the Terminal Cover on an IP20/NEMA Type 1 Drive
(Models CIMR-VBA0006F to BA0018F; 2A0008F to 2A0069F; 4A0001F to 4A0038F)
Ground Wire Length
mm (in)
Drive Model
CIMR-V
Single-Phase
200 V Class
Three-Phase
200 V Class
Three-Phase
400 V Class
150 (5.9)
BA0001
BA0002
BA0003
2A0001
2A0002
2A0004
2A0006
200 (7.9)
BA0006
BA0010
BA0012
BA0018
2A0010
2A0012
2A0020
4A0001
4A0002
4A0004
4A0005
4A0007
4A0009
4A0011
250 (9.8)
2A0030
2A0040
4A0018
4A0023
400 (15.7)
2A0056
2A0069
4A0031
4A0038
V1000
V1000
Modbus_conditional_E.fm 15 ページ 2012年3月7日 水曜日 午前11時31分