15 European Standards
90 YASKAWA TOEPC71061723A YASKAWA AC Drive CR700 Quick Start Guide
Figure 15.3 Wiring Example for DC Power Supply Input
Note:
• Install a fuse for each drive when operating more than one drive. If one fuse blows, replace all fuses.
• Install the external filter (system) to comply with the EMC Directive.
• Do not ground the main circuit bus.
Refer to Table 15.6 and Table 15.7 for the recommended fuses.
Three-Phase 200 V Class
Table 15.6 Recommended Fuse (Three-Phase 200 V Class)
Drive Model
Fuse
Manufacturer: Bussmann
Model Qty
2003 FWH-45B 2
2005 FWH-45B 2
2008 FWH-45B 2
2011 FWH-100B 2
2014 FWH-100B 2
2018 FWH-100B 2
2025 FWH-125B 2
2033 FWH-150B 2
2047 FWH-200B 2
2060 FWH-250A 2
2075
FWH-250A
FWH-300A
*1
2
2088
FWH-250A
FWH-275A
*1
2
2115
FWH-300A
FWH-350A
*1
2
2145
FWH-350A
FWH-450A
*1
2
2180
FWH-450A
FWH-600A
*1
2
2215
FWH-600A
FWH-700A
*1
2
2283
FWH-800A
FWH-1000B
*1
2
2346 FWH-1000B 2
2415 FWH-1000B 2
*1 Yaskawa recommends a fuse with a large rated current for applications with repeated loads.