Appendix J  Terminology
A-44
Appendix J Terminology
 Phase-C Pulse
The encoders mounted on Yaskawa’s servomotors output three types of pulse data, phase-A, -B, and -C. Phase-C pulse 
is a signal that reverses once per motor rotation and is called Zero-point Pulse.
 POSMAX
Reset position of infinite length axis
Refer to 4.4.1  Motion Fixed Parameter Details for details.
 Override
The original meaning of Override is annulling. In descriptions on Machine Controllers, override means overwriting the 
setting.
 Machine Coordinate System
The basic coordinate system set by executing the motion command ZRET (Zero Point Return) or ZSET (Set Zero 
Point). The Machine Controller manages positions using the Machine Coordinate System.
With a system using an incremental encoder, or absolute encoder as the incremental encoder, the Machine Coordinate 
System is automatically set by the first zero point return operation after the power turns ON.
With the system using an absolute encoder, it is automatically set after the power turns ON.
 Deceleration LS
Limit switch for deceleration.
For SERVOPACKs, deceleration LS for zero point return is connected to the Zero Point Return Deceleration signal 
DEC.
 Absolute Mode
One of target position (CPOS) coordinate data setting methods for position control. Target position (CPOS) coordinate 
data is directly set in Absolute Mode.
Refer to 5.1.4  Position Reference for details.
 Incremental Addition Mode
One of the target position (CPOS) coordinate data setting methods for position control. Target position (CPOS) coordi-
nate data is set by adding the movement amount to the previous position reference value in Incremental Addition 
Mode.
Refer to 5.1.4  Position Reference for details.
 Infinite Length Axis
An axis that employs the infinite length position control method, which resets the position data after one motor rota-
tion.
Refer to 5.1.3  Axis Type Selection for details.
 Infinite Length Position Control
This control method is used to perform position control without limiting the movement range for movements such as 
rotation in one direction.
Refer to 5.1.3  Axis Type Selection for details.
 Finite Length Axis
An axis that employs the finite length position control method or infinite length position control that does not reset the 
position data after one motor rotation to move in one direction.
Refer to 5.1.3  Axis Type Selection for details.