EasyManuals Logo

YASKAWA MP23 Series User Manual

YASKAWA MP23 Series
557 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #180 background imageLoading...
Page #180 background image
6.2 Motion Command Details
6.2.2 Latch Target Positioning (EX_POSING) (External Positioning)
6-15
Motion Commands
[ b ] Execution when Aborted
[ c ] Execution when Aborting by Changing the Command
[ d ] Execution when an Alarm Occurs
OW08 = 2 (EX_POSING)
IW08 = 2 (EX_POSING)
IW09, bit 0 (BUSY)
Undefined length of time
IW09, bit 8 (COMPLETE)
IW09, bit 3 (FAIL)
IW0C, bit 0 (DEN)
IW0C, bit 1 (POSCOMP)
1 scan
OW09, bit 1 (ABORT)
Undefined length of time1 scan
OW08 = 2 (EX_POSING)
IW08 = 2 (EX_POSING)
IW09, bit 0 (BUSY)
IW09, bit 8 (COMPLETE)
IW09, bit 3 (FAIL)
IW0C, bit 0 (DEN)
IW0C, bit 1 (POSCOMP)
Undefined length of time
Alarm
1 scan
OW08 = 2 (EX_POSING)
IW08 = 2 (EX_POSING)
IW09, bit 0 (BUSY)
IW09, bit 8 (COMPLETE)
IW09, bit 3 (FAIL)
IW0C, bit 0 (DEN)
IW0C, bit 1 (POSCOMP)

Table of Contents

Other manuals for YASKAWA MP23 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA MP23 Series and is the answer not in the manual?

YASKAWA MP23 Series Specifications

General IconGeneral
BrandYASKAWA
ModelMP23 Series
CategoryController
LanguageEnglish

Related product manuals