3.4 Self-configuration and Definition Files
3.4.5 Precautions When Saving SERVOPACK Parameters
3-35
Self-configuration and Created Definition Files
( 7 ) Saving Data to Flash Memory
The data flow for SERVOPACK parameters is as follows when saving the parameters to flash memory on the MPE720:
• The Machine Controller writes the parameters data (Input Data) held in SDRAM to flash memory.
Save to flash memory also after having changed set data of SERVOPACK parameter.
indicates data has been written.
3.4.5 Precautions When Saving SERVOPACK Parameters
Before executing saving operation in the SERVOPACK Tab Page in any cases excluding the SERVOPACK replace-
ment, always select Edit - Copy Current Value to copy the values in Current to Input Data.
MECHATROLINK
RAM
EEP
-ROM
SRAM
SDRAM
Input
Data
MPE720 online
HDD in personal computer
Display
Current
Value
Input
Data
Flash
Memory
System
Software
Control
Software
SERVOPACK Parameters
(All Axes)
Parameters
SERVOPACK SERVOPACK
Send Send
Machine Controller

Table of Contents

Other manuals for YASKAWA MP23 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA MP23 Series and is the answer not in the manual?

YASKAWA MP23 Series Specifications

General IconGeneral
BrandYASKAWA
ModelMP23 Series
CategoryController
LanguageEnglish

Related product manuals