EasyManuals Logo

YASKAWA MP23 Series User Manual

YASKAWA MP23 Series
557 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #240 background imageLoading...
Page #240 background image
6.2 Motion Command Details
6.2.19 Alarm History Monitor (ALM_HIST)
6-75
Motion Commands
( 4 ) Timing Charts
[ a ] Normal End
[ b ] Error End
OW08 = 20 (ALM_HIST)
IW08 = 20 (ALM_HIST)
IW09, bit 0 (BUSY)
IW2D
Alarm code (0) Alarm code (0)
IW09, bit 8 (COMPLETE)
IW09, bit 3 (FAIL)
Undefined length
of time
Specified
alarm code
Alarm code (0) Alarm code (0)
OW08 = 20 (ALM_HIST)
IW08 = 20 (ALM_HIST)
IW09, bit 0 (BUSY)
IW2D
IW09, bit 8 (COMPLETE)
IW09, bit 3 (FAIL)
Undefined length
of time
Alarm
code (0)

Table of Contents

Other manuals for YASKAWA MP23 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA MP23 Series and is the answer not in the manual?

YASKAWA MP23 Series Specifications

General IconGeneral
BrandYASKAWA
ModelMP23 Series
CategoryController
LanguageEnglish

Related product manuals