7.2 Motions After Switching Motion Commands
7.2.11 Switching from PHASE
7-42
PHASE
VELO
PHASE will immediately switch to VELO, and the control mode will change from phase
control mode to speed control mode. The moving amount stored in the acceleration/decel-
eration filter will be reset to 0.
After PHASE has switched to VELO, the VELO command will be executed
without the acceleration/deceleration filter. To enable the acceleration/decel-
eration filter, hold the PHASE operation by executing an NOP command or
other commands. Then, when the Discharging Completed bit (IW0C, bit
0) turns ON, execute a VELO command.
TRQ
PHASE will immediately switched to TRQ, and the control mode will be changed from
phase control mode to torque control mode.
PHASE PHASE operation will continue.
(cont’d)
Switched From Switched To Operation
PHASE VELO
PHASE VELO
Phase control mode Speed control mode
PHASE VELO
The speed will smoothly change.
(The speed at the time the motion com-
mand is switched will increase/decrease
until it reaches the target speed of VELO.)
The acceleration/deceleration filter will
be canceled.
Motion command
Motion command
response
PHASE TRQ
PHASE TRQ
Phase control mode Torque control mode
PHASE TRQ
The reference value of the TRQ command
will be output as is regardless of the speed
when the motion command is switched.
Motion command
Motion command
response

Table of Contents

Other manuals for YASKAWA MP23 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA MP23 Series and is the answer not in the manual?

YASKAWA MP23 Series Specifications

General IconGeneral
BrandYASKAWA
ModelMP23 Series
CategoryController
LanguageEnglish

Related product manuals