11.2 Specifications of Options and Peripheral Devices
11 - 7
Table
11.4 Optional Cards (Continued)
Type Name Code No. Descriptions Manual No.
PG-A2
73600-A012X
Used for V/f control. Speed feedback is performed using the PG
attached to the motor to compensate for speed fluctuations caused
by slipping.
S A-phase pulse (single pulse) input (voltage, complementary,
open-collector input)
S Maximum input frequency: 32767 Hz
S Pulse monitor output: +12 V, 20 mA
(PG power supply output: +12 V, 200 mA max.)
TOE-C736-40.1
c
onnector)
C
ontrol Cards
PG-B2
73600-A013X
S Used for flux vector control.
S A-, B-phase input (complimentary input)
S Maximum input frequency: 32767 Hz
S Pulse monitor output: Open-collector
(PG power supply output: +12 V, 200 mA max.)
TOE-C736-40.2
Built-in (connect to c
o
PG Speed C
o
PG-D2
73600-A014X
S Differential input.
S A-phase pulse (differential pulse) input, for V/f control
S Maximum input frequency: 300 kHz
S Input: Conforms to RS-422
S Pulse monitor output: RS-422
(PG power supply output: +5 or +12 V, 200 mA max.)
TOE-C736-40.3
PG-X2
73600-A015X
Used for flux vector control.
S A-, B-, Z-phase pulse (differential pulse) input
S Maximum input frequency: 300 kHz
S Input: Conforms to RS-422
S Pulse monitor output: RS-422
(PG power supply output: +5 or +12 V, 200 mA max.)
TOE-C736-40.4
Synchronous Phase Control
Card
SP-A2
73600-A016X
Connector to Inverter to enable synchronized startup control with
the motor. An external voltage detection transformer
(CPT005845) is required.
TOE-C736-40.5