46
The following procedures show how to change variable torque motor selection to
constant torque motor selection and set the motor related constants.
Table 13 Motor Related Constants Setting
Step Description Key Sequence Digital Operator Display
1
Power ON
Displays speed reference value.
G
REMOTE LEDs
(SEQ, REF) ON.
2
Move to program mode.
When inputting the values other than motor
nameplate
values,
execute
steps
to be-
low.
3
7
DRIVE
PRGM
Constant No. display
3
Move to access level (A1-01).
RESET
4
Verify the set value.
DATA
ENTER
5
Change to ADVANCED.
RESET
6
Write-in the value.
DATA
ENTER
Displays for 0.5 seconds.
Setting completed.
7
Return to constant No. display.
DSPL
8
Variable torque/constant torque motor selection
Move to variable torque/constant torque
motor selection (E1-14).
RESET
9
Verify the set value.
DATA
ENTER
(Initial setting: variable torque motor)
10
Select constant torque motor.
RESET
11
Write-in the value.
DATA
ENTER
Displays for 0.5 seconds.
Setting completed.
12
Return to constant No. display.
DSPL
(Cont’d)