EasyManua.ls Logo

YASKAWA VS-686SS5 - With Contact Output, Open Collector Output

YASKAWA VS-686SS5
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
APPENDIX 3 TYPICAL CONNECTION DIAGRAM
83
3.4 WITH CONTACT OUTPUT, OPEN COLLECTOR OUTPUT
U (T1)
V (T2)
W (T3)
MCCB
3-Phase
Power Supply
380 to 460V
50/60Hz
R
S
T
R (L1)
S (L2)
T (L3)
Motor
M
3
4
5
6
7
8
20
19
Fault Contact Output
250 VAC 1 A or less
30 VDC 1 A or less
18
(12)
21
22
Analog
Monitor 1
23
10
9
Multi-function
Output Common
27
Open Collector 2
(Speed Agree Signal
at Factory Setting)
48 V 50mA or less
26
Open Collector 1
(Zero Speed Signal
at Factory Setting)
48 V 50mA or less
25
Sequencer (External)
Surge
Suppressor
250 VAC Max
30 VDC Max
Fly-wheel
Diode
48 VDC Max
Fly-wheel
Diode
48 VDC Max
Fly-wheel
Diode
B1 B2¨ 1 ©¨ 2
Forward Run/Stop
Reverse Run/Stop
Factory
Setting
External Fault
Fault Reset
Multi-step Speed Setting 1
(Master/Aux Change)
Multi-step Speed
Setting 2
Jog Reference
External Baseblock
2k
2k
0 to +10 V
4to20mA
P
0 to +10 V
P
0V
P
17 (Aux Speed Ref. at
Factory Setting)
15 Speed Setting Power
Supply +15V 20mA
11
0V
1 Forward Run when
CLOSED
2 Reverse Run when
CLOSED
Multi-function
Contact Input
Sequence Common
Terminal (0V)
12 Shield Sheath
Connection Terminal
13 Master Speed Ref.
0 to 10V (20k)
14 Master Speed Ref.
4 to 20mA (250)
33 Speed Setting
Power Supply
-15V 20mA
16 Multi-function Analog Input
0 to 10V (20)
Ground (100 or less)
+
AM
+
SM
Multi-function Analog Output
-10 to +10 V 2mA
(Rotation Speed at Factory
Setting)
Multi-function Analog Output
-10 to +10V 2mA
(Output Current at Factory
Setting)
Multi-function Contact
Output
250 VAC 1 A or less
30 VDC 1A or less
(Signal during Running
at Factory Setting)
Analog
Monitor 2
Short-circuit Bar
(Provided as
Standard)
Note: Main circuit terminals are indicated by 200V 7.5kW / 400V 15kW models or below.
VS-686SS5
External
Speed
Reference

Table of Contents