EasyManua.ls Logo

YASKAWA VS-686SS5 - Table 15 Checking the Motor Speed Detection; PG Zero-pulse Adjustment

YASKAWA VS-686SS5
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
Adjust zero-pulse when replacing PG or motor (i.e. when relative position of connection be-
tween motor and PG).
The operation pattern below shows PG zero-pulse adjustment method. If an error is dis-
played during adjustment, refer to APPENDIX 5.
Forward Run
at Low Speed
(30 min
-1
)
Power ON Adjustment Start
Pre-adjustment
Processing after
Adjustment
Adjustment Complete
Automatic Operation
1
2
3
4
5
Forward Run
at Low Speed
(30 min
-1
)
Fig. 22 Operation Pattern of PG Zero-pulse Adjustment
Table 16 PG Zero-pulse Adjustment
Step Description Key Sequence Digital Operator Display
1
Power ON
• Displays speed reference value.
G
REMOTE LEDs (SEQ, REF) ON.
A1-02=06 (Control method: flux vector)
2
Pre-adjustment
• Move to program mode.
DRIVE
PRGM
Constant No. display
• Move to tuning item selection (T1-03).
RESET
• Verify the set value. (Go to : for “01.”)
DATA
ENTER
• Change the value to “01” (adjusting of PG
zero-pulse only).
RESET
• Write-in the value.
DATA
ENTER
Displays for 0.5 seconds.
(Cont’d)
NOTE