28
34 0122H
Parameter selection at
electronic thermal motor
protection
Setting unit: 1min
Setting range: 1 ~ 60min
8 min 94
35 0123H
Cooling fan operation
selection
0: Controls the cooling fan OFF / ON
1: Operates when power is ON.
096
36 0124H
Multi-function input
selection 2
1: Not used
2: Reverse run reference (2 wire
sequence)
3: External fault (N. O. contact input)
4: External fault (N. C. contact input)
5: Fault reset
6: Multi speed reference 1
8: Multi speed reference 2
7: Multi speed reference 3
9: Not used
10: Jog reference
11: Accel / decel time switching refer-
ence
12: External baseblock reference
(N. O. contact input)
13: External baseblock reference
(N. C. contact input)
14: Speed search command from Max.
output frequency
15: Speed search command set fre-
quency
16: Accel / decel hold
17: Local / remote switching
18: Communication / control circuit ter-
minal switching
19: Emergency stop fault
(N. O. contact input)
20: Emergency stop alarm
(N. O. contact input)
21: Emergency stop fault
(N. C. contact input)
22: Emergency stop alarm
(N. C. contact input)
23~ 33: Unused
282
37 0125H
Multi-function input
selection 3
0: Forward / reverse command
(3 wire sequence)
Others are the same as parameter 36
584
38 0126H
Multi-function input
selection 4
Same as parameter 36 3 84
39 0127H
Multi-function input
selection 5
Same as parameter 36
34: Up/down reference
35: Self-test
(Note: valid power ON / OFF)
684
No.
Register
No. for
Trans-
mission
Name Description
Initial
Setting
*User
Setting
Ref.
Page

Other manuals for YASKAWA VS MINI J7