10.2 Meaning and Function of Pr(RC2)-001 Terminal
10-4
HW0480311
HW0480311
10.2 Meaning and Function of Pr(RC2)-001 Terminal
The following describe the cable number of the connection terminal block and corresponding
signals.
10.2.1 TB2 Terminal
No.
Connection
Terminal
Block Cable
No.
Signal
Meaning
Function
Directi
on
*1
1209
Ammeter
terminal
Outputs 600A,
60mV.
W
R
2211
3526
Voltmeter
terminal
Directly outputs
the output
voltage.
W
R
4527
5
Reserved
−−
6
*1
"R" indicates the robot side while "W" indicates
the welding source side.
The external meters connected to the TB2 terminal are analog meters of ammeter (600A /
60mV) and voltmeter (75V). Values of the ten's volts for wire stick or ground detection at
the robot controller side may be displayed in the analog voltmeter, which is not a failure of
the device.
• The output voltage(600A/60mv) of the ammeter terminal is different
from the MOTOWELD-EL350.
TB2
A
V
209
211
526
527
20W
10K
Ω
NOTE
CAUTION