12.2 Confirmation of DIP Switch Set Status
12-3
HW0480311
HW0480311
12.2 Confirmation of DIP Switch Set Status
By referring to the information: "d-1" to "d-4" which is displayed in the Diagnosis mode, the
setting status of DIP switch on the PR(CR)-008 board of welding source inside can be
confirmed without removing the cover of the welding source.
Fig. 19 DIP Switch of MOTOWELD-EH500
For displaying the DIP switch status, ON/OFF state of each switch is displayed with 0/1 bit
data.
Fig. 20 Display of DIP Switch Set Status
The figure " Fig. 20 Display of DIP Switch Set Status " shows that the switches No.2, 3, and 6
of DSW3 are ON.
If the display of Diagnosis mode is different from the actual DIP switch setting, there may
be failure on the Pr(CR) board or Pr(MB) board. Replace the board.
8
7
65
4
3
21
DSW No. : 1 to 4
ON/OFF state of each switch : 1=ON / 0=OFF
NOTE