12.3 Confirmation of Software Version
12-4
HW0480311
HW0480311
12.3 Confirmation of Software Version
By referring to the information: "C-1", "C-2", and "C-3" which is displayed in the Diagnosis
mode, the software version which is loaded in the welding source can be confirmed.
• C-1: Main CPU 1 Software Version
• C-2: Sub CPU 2 Software Version
• C-3: Memory Software Version
The software version is displayed as shown below.
Fig. 19 Display of Software Version
The figure " Fig. 19 Display of Software Version " shows that the software version of the main
CPU is 3.20-000-6.
• For main circuit board: Pr(MB)-021 which is installed in MOTOWELD-
EH500, make sure that "6" is displayed in the model NO. of the software
version display.
If welding is performed with the main circuit board: Pr(MB), whose model No. is other than
"6", installed in the welding source, it may results in damage to the welding source.
CPU No. : 1=CPU1, 2=CPU2, 3=Memory
Software version No. : {. {{-{{
Model No. :
(6 represents EH500-6N0.)
CAUTION