Yealink IP Phones Auto provisioning Guide
194
Parameter
Permitted
Values
Descriptions
Web Setting Path
account.X.blf.s
ubscribe_peri
od =
(SIP-T28P/T48G
/T46G: X
ranges from 1
to 6.
SIP-T26P/T22P/
T42G/T41P: X
ranges from 1
to 3.
SIP-T21P/T20P:
X ranges from
1 to 2.
SIP-T19P: X=1.)
Integer from
30 to
2147483647
It configures the period (in seconds) of
the BLF subscription for account X.
The default value is 1800.
account.X.blf.s
ubscribe_even
t =
(SIP-T28P/T48G
/T46G: X
ranges from 1
to 6.
SIP-T26P/T22P/
T42G/T41P: X
ranges from 1
to 3.
SIP-T21P/T20P:
X ranges from
1 to 2.
SIP-T19P: X=1.)
0 or 1
It configures the event of the BLF
subscription for account X.
0-Dialog
1-Presence
The default value is 0.
account.X.sip_
server_type =
(SIP-T28P/T48G
/T46G: X
ranges from 1
to 6.
SIP-T26P/T22P/
T42G/T41P: X
ranges from 1
0, 2, 4 or 6
It configures the SIP server type for
account X.
0-Default
2-BroadSoft
4-Cosmocom
6-UCAP
The default value is 0.
Account->
Advanced->SIP
Server Type