<3. Installation>
36
IM 01C25A01-01E
IMPORTANT
h= × 0.102 [mm]
(P–P0)
ds
Wetted parts
material
code
Capillary
length
Process connection size
code
2, 8 3 4,W
SW
UW
Wetted parts
material
code
Capillary
length
Process connection size
code
2, 8 3 4,W
SW
code
A, 1, 4 B C, 2 D E
1.92
F0308.ai
P
Low pressure side
High
pressure
side
(+)
(–)
0
h
Figure 3.8 Example of Installation to Tank
(Caution on Installation)
3.4 Mounting the Flushing
Connection Ring
3.4.1 Mounting to Pressure Detector
Section
Ring holder
Spiral gasket
F0309.ai
View from pressure
detector section
Groove for
installing
spiral gasket
Pressure-detector section
Vent/Drain plug
Ring
Figure 3.9 Mounting to Pressure Detector Section