Do you have a question about the YOKOGAWA YTA Series and is the answer not in the manual?
Stability | ±0.1% of URL per year |
---|---|
Ambient Temperature Limits | -40 to 85 °C (-40 to 185 °F) |
Housing Material | Aluminum alloy or Stainless steel |
Model | YTA Series |
Input | Thermocouple (TC), RTD, DC Voltage |
Output | 4-20 mA DC |
Communication Protocol | HART, FOUNDATION Fieldbus, BRAIN |
Accuracy | ±0.1% of span |
Power Supply | 10.5 to 42 V DC (HART) |
Display | LCD (optional) |
Enclosure Rating | IP66, IP67, NEMA 4X |
Essential instructions for safe operation, installation, wiring, and maintenance.
Warnings and precautions regarding safety and product modifications.
Specific requirements and differences for installing explosion-protected transmitters.
Recommendations for choosing an optimal installation location for stability and accuracy.
Important considerations for wiring to prevent electrical noise and ensure safety.
Explains the two-wire loop construction for general-use and intrinsically safe types.
Wiring diagrams showing connections for different sensor types and configurations.
A flowchart to diagnose and resolve common issues with the transmitter.
Lists common alarms, their causes, and corresponding actions for resolution.
Details on optional intrinsically safe approvals including ATEX, FM, IECEx, and CSA.
How to connect and the requirements for using a HART communicator with the YTA70P.
Overview of available parameters for configuring the YTA70P via HART.
Parameters for diagnostics, status checks, calibration, and device reset.
Comprehensive setup parameters including HART, sensor configuration, and output conditions.
Comprehensive list of parameters for process and dynamic variables.
Parameters for calibration, write protection, DV logging, simulation, and device reset.
List of setup parameters for HART, variable mapping, and range configuration.
Settings for analog output range, error values, broken/shorted sensor conditions.
List of diagnostic and service status parameters and their descriptions.
Parameters related to process sensor configuration, limits, and error detection.
Parameters for analog output conditions, range, and error detection.
Installation drawing and requirements for ATEX certification of the YTA70P.
Installation drawing and entity concept criteria for FM certification of the YTA70P.
Installation drawing and requirements for IECEx certification of the YTA70P.
Installation drawing and notes for CSA certification of the YTA70P.