EasyManuals Logo
Home>YOKOGAWA>Transmitter>YTA Series

YOKOGAWA YTA Series User Manual

YOKOGAWA YTA Series
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
8-11
IM 01C50C05-01EN
F0803-11.ai
Output Condition Analog output
HART output
Output Range
Sensor Error Values
Loop current
Loop current mode
Loop test
D/A trim
Override D/A trim
Loop current mode
Poll addr
Num req preams
Num resp preams
AO 0%
AO 100%
AO Lower Limit
AO Upper Limit
Set limits = NAMUR
Error detection
Broken Sensor
Shorted Sensor
Broken Sensor Value
NAMUR down
NAMUR up
Shorted Sensor Value
NAMUR down
NAMUR up