Data Acquisition System GM
First Step Guide
IM 04L55B01-02EN
4th Edition
Contents
Introduction ................................................................................. 2
Checking the Package Contents ................................................. 3
MODEL and SUFFIX Codes ....................................................... 4
Standard Accessories ................................................................. 5
Module Notation .......................................................................... 6
GM Overview ............................................................................. 6
GM Conguration ........................................................................ 6
Module Version and Notes on Linking .......................................... 6
Channel Names .......................................................................... 7
Operating Procedure ........................................................8
Basic Operation .............................................................. 10
Names of the GM10 Parts ..........................................................10
Conguring the GM via Ethernet Communication .......................10
Conguring the GM via USB Communication .............................12
Starting to Measure and Record .................................................12
Installation.......................................................................13
Installation Location ....................................................................13
Installation Procedure .................................................................13
Unit External Dimensions (Unit: mm) ...........................................13
Installing on a Desktop or Floor.................................................. 14
Mounting on a DIN Rail .............................................................. 14
Mounting on a Wall .................................................................... 14
Wiring .............................................................................. 15
Precautions to Be Taken While Wiring ........................................16
Removing and Attaching a Terminal Cover .................................16
Removing and Attaching a Terminal Block ..................................16
Wiring Procedure .......................................................................17
Internal dimensions of the M3 screw terminal (unit: mm) .............17
Wiring the Clamp Terminal ..........................................................17
Wiring to a GX90XA Analog Input Module ..................................17
Wiring to a GX90XD Digital Input Module....................................19
Wiring to a GX90YD Digital Output Module .................................19
Wiring to a GX90WD Digital I/O Module .................................... 20
Wiring to a GX90XP Pulse Input Module.................................... 20
Wiring to a GX90YA Analog Output Module ............................... 20
Wiring to a GX90UT PID Control Module ................................... 20
Connecting to the RS-422/485 Connector
(/C3 option) ............................................................................21
Connecting to the USB Port .......................................................21
Connecting to the Ethernet Port .................................................21
Wiring the Power Supply ........................................................... 22
Turning the Power On and Off ................................................... 23
Connecting GX90EX Expansion Modules ................................. 23
Bluetooth Connection Procedure (/C8 option) ............................ 24
Users
Manual
Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA GM90PS and is the answer not in the manual?

YOKOGAWA GM90PS Specifications

General IconGeneral
BrandYOKOGAWA
ModelGM90PS
CategoryOther
LanguageEnglish

Summary

Introduction and Safety Precautions

Safety Precautions

Important warnings regarding safe operation and handling of the GM.

Operating Procedure and System Setup

GM Operation and Configuration

Measurement and Recording Configuration

Signal Input Configuration

Guide on specifying input types, ranges, and settings for analog channels.

GM Configuration and Operation

Starting Recording and Measurement

Methods to start recording and measuring via web, configurator, or START key.

GM Installation Guide

Desktop or Floor Mounting

DIN Rail Mounting

Wall Mounting

Wiring Procedures and Precautions

Wiring Safety Warnings

Crucial safety warnings related to wiring procedures.

Wiring Precautions

Wiring Procedures and GX90 XA Module

GX90 XA Analog Input Wiring

Details terminal diagrams, wiring diagrams, and arrangement for GX90XA.

Digital Input;Output Module Wiring

GX90 XD Digital Input Wiring

Terminal arrangement and internal circuit for GX90XD digital input.

GX90 YD Digital Output Wiring

Terminal diagram and arrangement for GX90YD digital output.

Module Wiring Diagrams and Arrangements

Analog, PID, and Output Wiring

Diagrams for Analog Output, PID Control, and Digital Output modules.

Digital, I;O, and Pulse Wiring

Diagrams for Digital Input/Output and Pulse Input modules.

Communication Port Connections and Wiring Diagrams

Power Supply Wiring

M4 Screw Terminal Wiring Precautions

Critical warnings for wiring power supply M4 screw terminals.

Power Supply Wiring Procedure

Step-by-step instructions for wiring the power supply.

Power Inlet Connection Precautions

Important warnings for connecting the power supply via the power inlet.

Power Cord Connection Procedure

Steps for connecting the supplied power cord.

Power On;Off and Expansion Modules

Power On;Off Safety Warnings

Safety warning regarding careless operation of the power switch.