EasyManua.ls Logo

York B1HA030A06 - Cooling Superheat at Compressor Suction; Heating Superheat at Compressor Suction; Outdoor Temperature

York B1HA030A06
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
035-16004-001-A-0202
10 Unitary Products Group
INDOOR DB
TEMPERATURE,
°F
OUTDOOR TEMPERATURE, °F
-100 102030405060
55 9.7 10.2 10.9 12.1 14.2 17.6 23.3 32.8
70 - - - 3.0 5.1 8.5 14.2 23.7
80 -----4.19.819.3
TABLE 8 - HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 600 CFM (B1HA018)
OUTDOOR
TEMPERATURE,
°F
INDOOR WB TEMPERATURE, °F
55 57 59 61 63 65 67 69 71 73 75
65 9.2 14.5 19.7 25.0 30.2 35.5 40.8 40.3 39.7 39.2 38.7
70 9.6 14.2 18.8 23.4 28.0 32.5 37.1 37.3 37.5 37.7 37.9
75 10.1 14.0 17.9 21.8 25.7 29.5 33.4 34.3 35.2 36.1 37.0
80 10.5 13.7 17.0 20.2 23.4 26.6 29.8 31.4 33.0 34.6 36.2
85 11.0 13.5 16.0 18.5 21.1 23.6 26.1 28.4 30.7 33.0 35.4
90 11.4 13.3 15.1 16.9 18.8 20.6 22.4 25.5 28.5 31.5 34.5
95 11.9 13.0 14.2 15.3 16.5 17.6 18.8 22.5 26.2 30.0 33.7
100 9.0 10.3 11.7 13.1 14.4 15.8 17.1 20.1 23.0 26.0 28.9
105 6.0 7.6 9.2 10.8 12.4 14.0 15.5 17.7 19.8 22.0 24.1
110 - - 6.7 8.5 10.3 12.1 13.9 15.3 16.6 18.0 19.3
115 - - - 6.3 8.3 10.3 12.3 12.9 13.4 14.0 14.5
TABLE 7 - COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 600 CFM (B1HA018)