Unitary Products Group 11
035-16004-001-A-0202
INDOOR DB
TEMPERATURE,
°F
HEATING SUPERHEAT AT COMPRESSOR SUCTION, °F
-100 102030405060
55 12.6 13.0 13.5 14.2 15.4 17.2 19.9 24.2
70 ----3.35.17.912.1
80 ------4.99.1
TABLE 10 - HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 800 CFM (B1HA024)
TABLE 9 - COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 800 CFM (B1HA024)
OUTDOOR
TEMPERATURE,
°F
INDOOR WB TEMPERATURE, °F
55 57 59 61 63 65 67 69 71 73 75
65 17.0 18.2 19.4 20.5 21.7 22.8 24.0 27.0 30.0 33.0 36.0
70 14.3 15.5 16.7 17.8 19.0 20.1 21.3 24.6 27.9 31.1 34.4
75 11.6 12.8 13.9 15.1 16.3 17.4 18.6 22.2 25.7 29.3 32.9
80 8.9 10.1 11.2 12.4 13.6 14.7 15.9 19.7 23.6 27.5 31.4
85 6.2 7.4 8.5 9.7 10.9 12.0 13.2 17.3 21.5 25.7 29.9
90 - - 5.8 7.0 8.2 9.3 10.5 14.5 19.4 23.9 28.3
95 ----5.56.67.812.5 17.3 22.1 26.8
100 -----5.46.310.4 14.6 18.7 22.9
105 -------8.311.815.4 19.0
110 -------6.29.112.1 15.0
115 --------6.48.811.1
OUTDOOR
TEMPERATURE,
°F
INDOOR WB TEMPERATURE, °F
55 57 59 61 63 65 67 69 71 73 75
65 17.0 20.0 22.9 25.9 28.9 31.8 34.8 39.0 43.1 47.3 51.5
70 14.3 16.9 19.5 22.2 24.8 27.5 30.1 34.2 38.2 42.3 46.4
75 11.5 13.9 16.2 18.5 20.8 23.1 25.4 29.4 33.4 37.3 41.3
80 8.8 10.8 12.8 14.8 16.7 18.7 20.7 24.6 28.5 32.3 36.2
85 6.1 7.7 9.4 11.0 12.7 14.4 16.0 19.8 23.6 27.4 31.1
90 - - 6.0 7.3 8.7 10.0 11.3 15.0 18.7 22.4 26.1
95 -----5.66.610.2 13.8 17.4 21.0
100 ------5.27.910.7 13.4 16.2
105 -------5.67.69.511.4
110 ---------5.66.7
115 -----------
INDOOR DB
TEMPERATURE,
°F
OUTDOOR TEMPERATURE, °F
-100 102030405060
55 15.3 15.6 16.0 16.8 17.9 19.6 22.2 26.2
70 ----3.24.97.511.5
80 ------4.58.5
TABLE 11 - COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,000 CFM (B1HA030)
TABLE 12 - HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,000 CFM (B1HA030)