12 Unitary Products Group
035-16004-001-A-0202
INDOOR DB
TEMPERATURE,
°F
HEATING SUPERHEAT AT COMPRESSOR SUCTION, °F
-100 102030405060
55 9.7 10.1 10.7 11.8 13.7 17.0 22.6 32.2
70 ----4.67.813.4 23.0
80 ------7.316.9
TABLE 14 - HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,200 CFM (B1HA036)
TABLE 13 - COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,200 CFM (B1HA036)
OUTDOOR
TEMPERATURE,
°F
INDOOR WB TEMPERATURE, °F
55 57 59 61 63 65 67 69 71 73 75
65 12.8 16.1 19.3 22.5 25.8 29.0 32.2 35.0 37.7 40.4 43.1
70 11.4 14.3 17.2 20.1 22.9 25.8 28.7 31.6 34.4 37.3 40.1
75 9.9 12.5 15.0 17.6 20.1 22.7 25.2 28.2 31.1 34.1 37.1
80 8.5 10.7 12.9 15.1 17.3 19.5 21.7 24.8 27.9 31.0 34.0
85 7.0 8.9 10.8 12.6 14.5 16.3 18.2 21.4 24.6 27.8 31.0
90 5.6 7.1 8.6 10.1 11.7 13.2 14.7 18.0 21.3 24.7 28.0
95 - 5.3 6.5 7.7 8.8 10.0 11.2 14.6 18.1 21.5 25.0
100 - - 5.1 6.0 6.9 7.8 8.7 11.7 14.7 17.7 20.7
105 -----5.66.28.711.313.9 16.4
110 -------5.87.910.0 12.2
115 ---------6.27.9
OUTDOOR
TEMPERATURE,
°F
INDOOR WB TEMPERATURE, °F
55 57 59 61 63 65 67 69 71 73 75
65 34.0 34.2 34.4 34.6 34.8 35.0 35.2 36.2 37.3 38.4 39.4
70 31.1 31.5 31.9 32.2 32.6 33.0 33.4 34.8 36.3 37.7 39.2
75 28.3 28.8 29.4 29.9 30.5 31.0 31.6 33.4 35.3 37.1 39.0
80 25.4 26.1 26.9 27.6 28.3 29.1 29.8 32.0 34.3 36.5 38.7
85 22.6 23.5 24.4 25.3 26.2 27.1 28.0 30.6 33.2 35.9 38.5
90 19.7 20.8 21.9 23.0 24.0 25.1 26.2 29.2 32.2 35.2 38.3
95 16.9 18.1 19.4 20.6 21.9 23.2 24.4 27.8 31.2 34.6 38.0
100 14.5 15.6 16.6 17.7 18.7 19.7 20.8 24.4 27.9 31.5 35.1
105 12.2 13.1 13.9 14.7 15.5 16.3 17.1 20.9 24.6 28.4 32.1
110 9.9 10.5 11.1 11.7 12.3 12.9 13.5 17.4 21.3 25.3 29.2
115 7.6 8.0 8.4 8.8 9.1 9.5 9.9 14.0 18.1 22.1 26.2
INDOOR DB
TEMPERATURE,
°F
OUTDOOR TEMPERATURE, °F
-100 102030405060
55 5.1 5.5 6.2 7.4 9.6 13.5 20.3 32.4
70 ----5.08.915.7 27.8
80 -----5.412.2 24.3
TABLE 15 - COOLING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,400 CFM (B1HA042)
TABLE 16 - HEATING SUPERHEAT AT COMPRESSOR SUCTION, AIRFLOW = 1,400 CFM (B1HA042)