PRODUCT NOMENCLATURE
20T Sunline 2000™ Model Number Nomenclature
B Q 240 C 00 A 2 A AA 1 A
Product Category Product Style
B = Heat Pump, Single Package A = Style A
Product Generation
1 = First Generation
Product Identifier
Q= R-22 Standard Efficiency Heat Pump
Installation Options
Additional Options
A = No Options Installed
(See Next Page)
Voltage B = Option 1
C = Option 2
2 = 208/230-3-60
D=Options1&2
Nominal Cooling
Capacity - MBH
4 = 460-3-60
E=Option3
5 = 575-3-60
F = Options 4
G = Options 1 & 3
240 = 20 Ton
H=Options1&4
J = Options 1, 2 & 3
K=Options1,2,&4
A= Std Motor/Drive
L = Options 1,3 & 4
B = Std Mtr/Drive/Single Input Econo
M = Options 1, 2, 3, & 4
C = Std Mtr/Drive/Single Input Econo/Power Exhaust*
N=Options2&3
D = Std Mtr/Drive/Motorized Damper
P = Options 2 & 4
Heat Type & Nominal Heat Capacity
F = Std Mtr/Drive/4" Filters
Q = Options 2, 3, & 4
C00 = Cooling Only. No field installed electric heat
G = Std Mtr/Drive/4" Filters/Single Input Econ
R=Options3&4
H = Std Mtr/Drive/4" Filters/Single Input Econ/Power Exhaust*
S=Option5
L = Std Mtr/Drive/BAS Ready Econ (No BAS Controller) w/2" Pleated Filters
T = Options 1 & 5
M = Std Mtr/Drive/BAS Ready Econ (No BAS Controller)/Power Exhaust w/2" Pleated Filters*
U = Options 1, 3, & 5
N = Hi Static Drive
V=Options1,4,&5
P = Hi Static Drive/Single Input Econo
W = Options 1, 3, 4, & 5
Electric Heat Options
Q = Hi Static Drive/Single Input Econo/Power Exhaust*
X = Options 3 & 5
E18 = 18 KW
R = Hi Static Drive/Motorized Damper
Y = Options 4 & 5
E36 = 36 KW
T = Hi Static Drive/4" Filters
Z=Options3,4,&5
E54 = 54 KW
U = Hi Static Drive/4" Filters/Single Input Econ
Options
E72 = 72 KW
V = Hi Static Drive/4" Filters/Single Input Econ/Power Exhaust*
1 = Disconnect
Y = Hi Static Drive/BAS Ready Econ (No BAS Controller) w/2" Pleated Filters
2 = Non-Pwr'd Conv Oultet
Z = Hi Static Drive/BAS Ready Econ (No BAS Controller)/Power Exhaust w/2" Pleated Filters*
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Airflow
York Brand

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York BQ240 and is the answer not in the manual?

York BQ240 Specifications

Power IconPower
voltage208/230 V, 460 V, 575 V
Refrigerant Components IconRefrigerant Components
transformers capacity75 VA
refrigerant circuitsdual
circuit breakers24 V