TABLE 6: D1EB036 SUPERHEAT CHARGING (IMPERIAL)
OUTDOOR
TEMPERATURE
(°F)
SUPERHEAT AT COMPRESSOR SUCTION (°F)
AIRFLOW = 1,300 CFM
INDOOR WB TEMPERATURE (°F)
55 57 59 61 63 65 67 69 71 73 75
65 21.1 21.6 22.1 22.7 23.2 23.8 24.3 25.3 26.4 26.9 27.4
70 19.5 20.0 20.6 21.1 21.7 22.2 22.8 24.0 25.1 25.7 26.3
75 17.9 18.5 19.0 19.6 20.2 20.7 21.3 22.6 23.9 24.6 25.2
80 16.3 16.9 17.5 18.0 18.6 19.2 19.8 21.2 22.7 23.4 24.1
85 14.7 15.3 15.9 16.5 17.1 17.7 18.3 19.9 21.4 22.2 23.0
90 13.1 13.8 14.4 15.1 15.8 16.4 17.1 18.7 20.3 21.2 22.0
95 11.5 12.2 12.9 13.7 14.4 15.2 15.9 17.6 19.3 20.1 20.9
100 9.1 9.6 10.2 10.7 11.2 11.8 12.3 15.0 17.6 18.9 20.2
105 6.7 7.1 7.4 7.7 8.1 8.4 8.8 12.4 16.0 17.8 19.6
110 - - - - - 5.0 5.2 9.7 14.3 16.6 18.9
115 -------7.1 12.6 15.4 18.2
TABLE 7: D1EB036 SUPERHEAT CHARGING (METRIC)
OUTDOOR
TEMPERATURE
(°C)
SUPERHEAT AT COMPRESSOR SUCTION (°C)
AIRFLOW = 0.61 M
3
/S
INDOOR WB TEMPERATURE (°C)
13 14 15 16 17 18 19 21 22 23 24
18 11.7 12.0 12.3 12.6 12.9 13.2 13.5 14.1 14.7 14.9 15.2
21 10.8 11.1 11.4 11.7 12.1 12.4 12.7 13.3 14.0 14.3 14.6
24 9.9 10.3 10.6 10.9 11.2 11.5 11.8 12.6 13.3 13.6 14.0
27 9.1 9.4 9.7 10.0 10.4 10.7 11.0 11.8 12.6 13.0 13.4
29 8.2 8.5 8.8 9.2 9.5 9.8 10.2 11.0 11.9 12.3 12.8
32 7.3 7.6 8.0 8.4 8.8 9.1 9.5 10.4 11.3 11.8 12.2
35 6.4 6.8 7.2 7.6 8.0 8.4 8.8 9.8 10.7 11.2 11.6
38 5.0 5.3 5.6 5.9 6.2 6.5 6.8 8.3 9.8 10.5 11.2
41 3.7 3.9 4.1 4.3 4.5 4.7 4.9 6.9 8.9 9.9 10.9
43 - - - - - 2.8 2.9 5.4 7.9 9.2 10.5
46 - - - - - - - 4.0 7.0 8.6 10.1