404912-UIM-A-0508
SINGLE PIECE
AIR HANDLERS
MODELS: F*FP
INSTALLATION MANUAL
ISO 9001
Certified Quality
Management System
TABLE OF CONTENTS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SPECIFIC SAFETY RULES AND PRECAUTIONS . . . . . . . . . . . . . . .2
SAFETY REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
HORIZONTAL DRAIN PAN CONVERSION . . . . . . . . . . . . . . . . . . . .3
DUCT CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
AIR FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SUSPENSION KITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
REFRIGERANT LINE CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . 6
ELECTRIC HEATERS AND OPERATING CONTROLS . . . . . . . . . . 6
LOW VOLTAGE CONTROL CONNECTION . . . . . . . . . . . . . . . . . . . 7
LINE POWER CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
BLOWER SPEED CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DRAIN CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
COIL CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
CONDENSATE DRAINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
LIST OF FIGURES
Plenum Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Filter Access & Drain Pan Conversion / Coil Baffle . . . . . . . . . . . . . . .4
Dimensions & Duct Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Typical Horizontal Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
TXV Bulb Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Bulb Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Electric Heaters in Horizontal Configuration - Right Hand Air Flow . . 7
Line Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Blower Speed Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cooling Models with Electric Heat Wiring . . . . . . . . . . . . . . . . . . . . . 14
Single Stage Heat Pump Control Wiring . . . . . . . . . . . . . . . . . . . . . . 14
LIST OF TABLES
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installed TXV Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Physical and Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Electrical Data - Cooling Only (50 & 60 Hz) . . . . . . . . . . . . . . . . . . . . .8
Conversion Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Electrical Data - 1 Ø - 208/230-1-60 . . . . . . . . . . . . . . . . . . . . . . . . . .9
Electrical Data - (For Single Source Power Supply) -
Copper Wire 1 Ø - 208/230-1-60 . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Electrical Data - (For Multi-Source Power Supply) -
Copper Wire 1 Ø - 208/230-1-601 . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electrical Data - 3 Ø - 208/230-3-60 . . . . . . . . . . . . . . . . . . . . . . . . . 11
Electrical Data - (For Single Source Power Supply) -
Copper Wire 3 Ø - 208/230-3-60 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Airflow Data for 230 Volt - Heat Pump Models . . . . . . . . . . . . . . . . . 12
Airflow Data for 208 Volt - Heat Pump Models . . . . . . . . . . . . . . . . . 13
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury
.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury
.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury.
It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.
This product must be installed in strict compliance with the installa-
tion instructions and any applicable local, state, and national codes
including, but not limited to building, electrical, and mechanical
codes.
Question and Answer IconNeed help?

Do you have a question about the York F4FP036H06T2A and is the answer not in the manual?

York F4FP036H06T2A Specifications

General IconGeneral
BrandYork
ModelF4FP036H06T2A
CategoryAir Handlers
Cooling Capacity3 Tons
Voltage208-230V
Phase1
Cabinet ConstructionGalvanized Steel
InsulationFoil-faced
Drain Connection3/4'' NPT
Width21 in.
Depth21 in
Maximum External Static Pressure0.8 in. wg
Filter Type1-inch throwaway
Refrigerant Connections3/8" Liquid Line, 3/4" Suction Line

Summary

Safety and Warning Guidelines

Safety Alert Symbol Definitions

Defines safety symbols (DANGER, WARNING, CAUTION) and their implications for user safety.

Installation Safety Warnings

Stresses proper installation, code adherence, and hazard avoidance for unit operation to prevent injury.

Installation Requirements and Site Preparation

Specific Safety Rules and Precautions

Outlines critical safety rules, electrical hazards, and safety requirements for installation.

Clearances and Location Considerations

Specifies required clearances for components and suitable installation locations for optimal performance.

Drain Pan Conversion and Coil Setup

Horizontal Drain Pan Conversion

Instructions for converting the drain pan for left-hand horizontal installation.

Drain Pan and Coil Cautions

Cautions regarding panel opening for secondary drain and coil baffle adjustment.

Ductwork and Refrigerant System Connections

Duct Connections and Warnings

Guidelines for connecting ductwork, including a warning about screw length.

Coil Metering Devices and TXV Bulb Installation

Introduces TXV metering devices and provides steps for TXV bulb installation.

Refrigerant Lines and Electric Heater Installation

Refrigerant Line Connection

Procedures for connecting refrigerant lines, pressure relief, and routing.

Electric Heater Installation and Controls

Covers standard controls, heater kit installation, and bypass jumper requirements.

Electrical Connections and Blower Speed

Low Voltage Control Connection

Instructions for connecting 24-volt power supply and control wiring.

Line Power Connections

Guidelines for making main power supply connections to the unit.

Blower Speed Connections

How to adjust blower motor speed for optimal airflow based on system requirements.