INSTALLATION
MANUAL
CAUTION: READ ALL SAFETY GUIDES BEFORE YOU
START TO INSTALL YOUR UNIT.
SAVE THIS MANUAL
SINGLE PIECE AIR HANDLERS
HEAT PUMP MODELS
F2RP / F2FP018 THRU 060
F3RP / F3FP018 THRU 060
COOLING MODELS
F2RC / F2FC 024 THRU 036
035-14520-001 Rev. B (0803)
TABLE OF CONTENTS
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . 2
INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
HORIZONTAL DRAIN PAN INSTALLATION /
CONVERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DUCT CONNECTORS . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AIR FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SUSPENSION KITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . 6
REFRIGERANT LINE CONNECTION . . . . . . . . . . . . . . . 7
ELECTRIC HEATERS & OPERATING CONTROLS . . . 8
LOW VOLTAGE CONTROL CONNECTION . . . . . . . . . . 8
LINE POWER CONNECTIONS . . . . . . . . . . . . . . . . . . . . 8
BLOWER SPEED CONNECTIONS . . . . . . . . . . . . . . . . 8
DRAIN CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . 19
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
COIL CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
CONDENSATE DRAINS . . . . . . . . . . . . . . . . . . . . . . . . 19
TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . 19

Questions and Answers

  • C
    crawfordjenniferAug 8, 2025
    Why does my York Air Handler blower run all the time?
    • C
      Carla PierceAug 9, 2025
      If the blower in your York Air Handler is running continuously, here's what might be happening and how to address it: * **Thermostat Setting:** Ensure that the thermostat fan switch is set to the “AUTO” position, not “ON”. * **Blower Delay:** The blower might be in its normal OFF delay, which lasts approximately 1 minute. Wait and see if it stops. * **Connectors and Limits:** Check the installation of the 6-pin connector. Also, inspect the limit switch connection. * **Variable Speed Tab:** Look for a broken variable speed break-out tab.
  • C
    Carrie LaraAug 14, 2025
    What to do if my York Air Handler has no heat or limited heating?
    • R
      Robin BaileyAug 14, 2025
      If your York Air Handler isn't providing enough heat, or no heat at all, here are a few things to check: 1. **Airflow:** Make sure that all registers are open and that there are no obstructions restricting airflow to either the supply or return registers. 2. **Filter:** Inspect the filter and replace it if it's dirty. 3. **Blower Motor:** Check to ensure the blower motor is functioning correctly. 4. **Safety Limit:** If the safety limit has opened 4 times, the control will prevent the heating element from operating for 1 hour. Allow the control to reset.
  • T
    Thomas CervantesAug 20, 2025
    How to troubleshoot no 2nd stage heat in York F2RP030?
    • M
      Maria TranAug 20, 2025
      If your York Air Handler is not providing 2nd stage heat, here’s what you should check: * **Connectors and Relays:** Inspect the 6-pin connector and the connections to the panel mount relays. * **Terminal Strip Connections:** Verify that both W1 and W2 are securely connected at the terminal strip.
  • M
    mmooreAug 27, 2025
    What to do if my York Air Handler has no 24V?
    • N
      Nicholas VegaAug 27, 2025
      If your York Air Handler has no 24V, here are a few things to check: * **4-Pin Connector:** Ensure the 4-pin connector is securely in place. * **Wiring:** Inspect and secure any loose wire connections from the control to the transformer (both 24V and 230V). * **Fuse:** Replace any blown fuse located on the control board.
  • S
    Sheri WintersSep 1, 2025
    Why does my York Air Handlers keep blowing fuses?
    • J
      Jesse HarrisonSep 1, 2025
      To address a blown fuse in your York Air Handler, check for low voltage shorts to C or ground from R, Y, G, W, or O.

Summary

General Information

Reference

Limitations

Inspection

Location

Horizontal Drain Pan Installation; Conversion

Dimensions

Duct Connectors

Air Filters

Suspension Kits

Coil Metering Devices

Orifice Metering Device

Details the procedure for installing and changing the orifice for refrigerant flow control.

Refrigerant Line Connection

Electric Heaters & Operating Controls

Low Voltage Control Connection

Line Power Connections

Blower Speed Connections

Drain Connections

Maintenance

Coil Cleaning

Instructions for washing the unit's heat exchange coil using a specific cleaning solution.

Lubrication

States that the blower motor bearings are permanently lubricated and require no additional oil.

Condensate Drains

Guide for checking condensate flow and ensuring primary drain is clear to prevent water issues.

Troubleshooting Guide