INSTALLATION
MANUAL
CAUTION: READ ALL SAFETY GUIDES BEFORE YOU
START TO INSTALL YOUR UNIT.
SAVE THIS MANUAL
SINGLE PIECE AIR HANDLERS
HEAT PUMP MODELS
F2RP / F2FP018 THRU 060
F3RP / F3FP018 THRU 060
COOLING MODELS
F2RC / F2FC 024 THRU 036
035-14520-001 Rev. B (0803)
TABLE OF CONTENTS
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . 2
INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
HORIZONTAL DRAIN PAN INSTALLATION /
CONVERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DUCT CONNECTORS . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AIR FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SUSPENSION KITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . 6
REFRIGERANT LINE CONNECTION . . . . . . . . . . . . . . . 7
ELECTRIC HEATERS & OPERATING CONTROLS . . . 8
LOW VOLTAGE CONTROL CONNECTION . . . . . . . . . . 8
LINE POWER CONNECTIONS . . . . . . . . . . . . . . . . . . . . 8
BLOWER SPEED CONNECTIONS . . . . . . . . . . . . . . . . 8
DRAIN CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . 19
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
COIL CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
CONDENSATE DRAINS . . . . . . . . . . . . . . . . . . . . . . . . 19
TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . 19

Questions and Answers

  • T
    Timothy FarmerAug 9, 2025
    Why does my York Air Handler blower run all the time?
    • D
      Deanna GalvanAug 9, 2025
      If the blower in your York Air Handler is running continuously, here's what might be happening and how to address it: * **Thermostat Setting:** Ensure that the thermostat fan switch is set to the “AUTO” position, not “ON”. * **Blower Delay:** The blower might be in its normal OFF delay, which lasts approximately 1 minute. Wait and see if it stops. * **Connectors and Limits:** Check the installation of the 6-pin connector. Also, inspect the limit switch connection. * **Variable Speed Tab:** Look for a broken variable speed break-out tab.
  • S
    Steven CarlsonAug 14, 2025
    What to do if my York Air Handler has no heat or limited heating?
    • S
      Samantha BriggsAug 14, 2025
      If your York Air Handler isn't providing enough heat, or no heat at all, here are a few things to check: 1. **Airflow:** Make sure that all registers are open and that there are no obstructions restricting airflow to either the supply or return registers. 2. **Filter:** Inspect the filter and replace it if it's dirty. 3. **Blower Motor:** Check to ensure the blower motor is functioning correctly. 4. **Safety Limit:** If the safety limit has opened 4 times, the control will prevent the heating element from operating for 1 hour. Allow the control to reset.
  • E
    Emily CarterAug 20, 2025
    How to troubleshoot no 2nd stage heat in York F2FP024?
    • M
      Michelle ThompsonAug 20, 2025
      If your York Air Handler is not providing 2nd stage heat, here’s what you should check: * **Connectors and Relays:** Inspect the 6-pin connector and the connections to the panel mount relays. * **Terminal Strip Connections:** Verify that both W1 and W2 are securely connected at the terminal strip.
  • J
    James RichAug 27, 2025
    What to do if my York Air Handler has no 24V?
    • E
      Erica HolmesAug 27, 2025
      If your York Air Handler has no 24V, here are a few things to check: * **4-Pin Connector:** Ensure the 4-pin connector is securely in place. * **Wiring:** Inspect and secure any loose wire connections from the control to the transformer (both 24V and 230V). * **Fuse:** Replace any blown fuse located on the control board.
  • D
    Danny CurrySep 1, 2025
    Why does my York F2FP024 Air Handlers keep blowing fuses?
    • V
      vtorresSep 1, 2025
      To address a blown fuse in your York Air Handler, check for low voltage shorts to C or ground from R, Y, G, W, or O.

Summary

LOCATION

HORIZONTAL DRAIN PAN INSTALLATION; CONVERSION

COIL METERING DEVICES

TXV Metering Device

Details on TXV installation and attachment to suction line.

Orifice Metering Device

Information on orifice installation and replacement procedures.

REFRIGERANT LINE CONNECTION

Brazing Procedures

Steps for connecting suction and liquid lines, including brazing.

ELECTRIC HEATERS & OPERATING CONTROLS

Low Voltage Control Connection

Instructions for connecting 24-volt power supply and low voltage wiring.

LINE POWER CONNECTIONS

Guidance on routing power leads and connecting conduit to the control box.

DRAIN CONNECTIONS

TROUBLESHOOTING GUIDE

York F2FP024 Specifications

General IconGeneral
Model NumberF2FP024
CategoryAir Handlers
Cooling Capacity2 Tons
Airflow800 CFM
Voltage208/230V
Phase1