INSTALLATION
MANUAL
CAUTION: READ ALL SAFETY GUIDES BEFORE YOU
START TO INSTALL YOUR UNIT.
SAVE THIS MANUAL
SINGLE PIECE AIR HANDLERS
HEAT PUMP MODELS
F2RP / F2FP018 THRU 060
F3RP / F3FP018 THRU 060
COOLING MODELS
F2RC / F2FC 024 THRU 036
035-14520-001 Rev. B (0803)
TABLE OF CONTENTS
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . 2
INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
REFERENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
HORIZONTAL DRAIN PAN INSTALLATION /
CONVERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DUCT CONNECTORS . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AIR FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SUSPENSION KITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . 6
REFRIGERANT LINE CONNECTION . . . . . . . . . . . . . . . 7
ELECTRIC HEATERS & OPERATING CONTROLS . . . 8
LOW VOLTAGE CONTROL CONNECTION . . . . . . . . . . 8
LINE POWER CONNECTIONS . . . . . . . . . . . . . . . . . . . . 8
BLOWER SPEED CONNECTIONS . . . . . . . . . . . . . . . . 8
DRAIN CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . 19
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
COIL CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
CONDENSATE DRAINS . . . . . . . . . . . . . . . . . . . . . . . . 19
TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . 19

Questions and Answers

  • S
    Susan RogersAug 8, 2025
    Why does my York Air Handler blower run all the time?
    • P
      Peter WilliamsAug 9, 2025
      If the blower in your York Air Handler is running continuously, here's what might be happening and how to address it: * **Thermostat Setting:** Ensure that the thermostat fan switch is set to the “AUTO” position, not “ON”. * **Blower Delay:** The blower might be in its normal OFF delay, which lasts approximately 1 minute. Wait and see if it stops. * **Connectors and Limits:** Check the installation of the 6-pin connector. Also, inspect the limit switch connection. * **Variable Speed Tab:** Look for a broken variable speed break-out tab.
  • T
    Tommy MarshAug 14, 2025
    What to do if my York Air Handler has no heat or limited heating?
    • W
      Wyatt GarciaAug 14, 2025
      If your York Air Handler isn't providing enough heat, or no heat at all, here are a few things to check: 1. **Airflow:** Make sure that all registers are open and that there are no obstructions restricting airflow to either the supply or return registers. 2. **Filter:** Inspect the filter and replace it if it's dirty. 3. **Blower Motor:** Check to ensure the blower motor is functioning correctly. 4. **Safety Limit:** If the safety limit has opened 4 times, the control will prevent the heating element from operating for 1 hour. Allow the control to reset.
  • K
    katherinelarsenAug 21, 2025
    How to troubleshoot no 2nd stage heat in York F2RP042 Air Handlers?
    • L
      Laura JonesAug 21, 2025
      If your York Air Handler is not providing 2nd stage heat, here’s what you should check: * **Connectors and Relays:** Inspect the 6-pin connector and the connections to the panel mount relays. * **Terminal Strip Connections:** Verify that both W1 and W2 are securely connected at the terminal strip.
  • D
    David MerrittAug 27, 2025
    What to do if my York Air Handler has no 24V?
    • Y
      ymooreAug 27, 2025
      If your York Air Handler has no 24V, here are a few things to check: * **4-Pin Connector:** Ensure the 4-pin connector is securely in place. * **Wiring:** Inspect and secure any loose wire connections from the control to the transformer (both 24V and 230V). * **Fuse:** Replace any blown fuse located on the control board.
  • C
    Carla SmithSep 1, 2025
    Why does my York F2RP042 keep blowing fuses?
    • V
      Virginia BrownSep 1, 2025
      To address a blown fuse in your York Air Handler, check for low voltage shorts to C or ground from R, Y, G, W, or O.

Summary

GENERAL INFORMATION & LIMITATIONS

INSPECTION & REFERENCE

Inspect unit for damage upon receipt and refer to associated documentation and warnings.

LIMITATIONS

Units must be wired and installed per national and local safety codes; specifies voltage limits.

INSTALLATION PROCEDURES

LOCATION, DRAINAGE & CLEARANCES

Guide to unit location, drainage, and required clearances for installation.

DIMENSIONS, COMPONENTS & METERING

Unit dimensions, duct connectors, air filters, suspension kits, and metering devices.

REFRIGERANT & ELECTRICAL CONNECTIONS

Procedures for refrigerant lines, electric heaters, controls, and power connections.

WIRING DIAGRAMS

Cooling & Heat Pump Wiring

Diagrams for cooling and heat pump wiring configurations.

MAINTENANCE & TROUBLESHOOTING

DRAINAGE & MAINTENANCE

Procedures for drain connections, filter/coil cleaning, and condensate checks.

TROUBLESHOOTING GUIDE

Table of common problems, their possible causes, and solutions.

York F2RP042 Specifications

General IconGeneral
Model NumberF2RP042
CategoryAir Handlers
Cooling Capacity3.5 Tons
Airflow1400 CFM
Voltage208/230V
Motor TypePSC
Filter Type1-inch throwaway
Cabinet ConstructionGalvanized Steel
InsulationFoil-faced

Related product manuals