EasyManua.ls Logo

York F4FP030H06T2A User Manual

York F4FP030H06T2A
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
404912-UIM-A-0508
SINGLE PIECE
AIR HANDLERS
MODELS: F*FP
INSTALLATION MANUAL
ISO 9001
Certified Quality
Management System
TABLE OF CONTENTS
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SPECIFIC SAFETY RULES AND PRECAUTIONS . . . . . . . . . . . . . . .2
SAFETY REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
HORIZONTAL DRAIN PAN CONVERSION . . . . . . . . . . . . . . . . . . . .3
DUCT CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
AIR FILTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SUSPENSION KITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
COIL METERING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
REFRIGERANT LINE CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . 6
ELECTRIC HEATERS AND OPERATING CONTROLS . . . . . . . . . . 6
LOW VOLTAGE CONTROL CONNECTION . . . . . . . . . . . . . . . . . . . 7
LINE POWER CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
BLOWER SPEED CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DRAIN CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
COIL CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
LUBRICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
CONDENSATE DRAINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
LIST OF FIGURES
Plenum Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Typical Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Filter Access & Drain Pan Conversion / Coil Baffle . . . . . . . . . . . . . . .4
Dimensions & Duct Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Typical Horizontal Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
TXV Bulb Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Bulb Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Control Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Electric Heaters in Horizontal Configuration - Right Hand Air Flow . . 7
Line Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Blower Speed Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Cooling Models with Electric Heat Wiring . . . . . . . . . . . . . . . . . . . . . 14
Single Stage Heat Pump Control Wiring . . . . . . . . . . . . . . . . . . . . . . 14
LIST OF TABLES
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installed TXV Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Physical and Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Electrical Data - Cooling Only (50 & 60 Hz) . . . . . . . . . . . . . . . . . . . . .8
Conversion Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Electrical Data - 1 Ø - 208/230-1-60 . . . . . . . . . . . . . . . . . . . . . . . . . .9
Electrical Data - (For Single Source Power Supply) -
Copper Wire 1 Ø - 208/230-1-60 . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Electrical Data - (For Multi-Source Power Supply) -
Copper Wire 1 Ø - 208/230-1-601 . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Electrical Data - 3 Ø - 208/230-3-60 . . . . . . . . . . . . . . . . . . . . . . . . . 11
Electrical Data - (For Single Source Power Supply) -
Copper Wire 3 Ø - 208/230-3-60 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Airflow Data for 230 Volt - Heat Pump Models . . . . . . . . . . . . . . . . . 12
Airflow Data for 208 Volt - Heat Pump Models . . . . . . . . . . . . . . . . . 13
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
SAFETY
This is a safety alert symbol. When you see this symbol on
labels or in manuals, be alert to the potential for personal
injury.
Understand and pay particular attention to the signal words DANGER,
WARNING, or CAUTION.
DANGER indicates an imminently hazardous situation, which, if not
avoided, will result in death or serious injury
.
WARNING indicates a potentially hazardous situation, which, if not
avoided, could result in death or serious injury
.
CAUTION indicates a potentially hazardous situation, which, if not
avoided may result in minor or moderate injury.
It is also used to
alert against unsafe practices and hazards involving only property dam-
age.
Improper installation may create a condition where the operation of
the product could cause personal injury or property damage.
Improper installation, adjustment, alteration, service or mainte-
nance can cause injury or property damage. Refer to this manual
for assistance or for additional information, consult a qualified con-
tractor, installer or service agency.
This product must be installed in strict compliance with the installa-
tion instructions and any applicable local, state, and national codes
including, but not limited to building, electrical, and mechanical
codes.
Question and Answer IconNeed help?

Do you have a question about the York F4FP030H06T2A and is the answer not in the manual?

York F4FP030H06T2A Specifications

General IconGeneral
Airflow (CFM)1200
Cooling Capacity (BTU/h)30000
Heating Capacity (BTU/h)30000
Voltage208-230
Phase1
Frequency (Hz)60
Motor TypePSC
Cabinet TypeGalvanized Steel
InsulationFoil-faced

Summary

Safety Information

Safety Symbols and Signal Words

Explains the meaning of safety symbols and signal words like WARNING and CAUTION.

Safety Rules and General Information

Specific Safety Rules

Details specific safety rules for installation and operation.

General Unit Information

Covers unit inspection, limitations, clearances, and location.

Horizontal Drain Pan Conversion

Drain Pan Conversion Procedure

Step-by-step guide for converting the unit's drain pan for different orientations.

Ductwork, Filters, and Suspension

Duct Connections

Guidelines for connecting supply and return air ducts.

Air Filters

Information on filter type, size, and installation.

Suspension Kits

Instructions for installing suspension kits for mounting.

Coil Metering and Refrigerant Lines

Coil Metering Devices

Details on factory-installed TXV metering devices and system matching.

Refrigerant Line Connections

Procedure for safely connecting refrigerant lines to the unit's coil.

Electric Heaters and Wiring

Electric Heaters and Controls

Information on installing electric heaters and their associated operating controls.

Low Voltage Control Wiring

Guidance on connecting the low voltage transformer and control wiring.

Line Power Connections

Instructions for making main power supply connections to the unit.

Blower Speed Adjustments

Blower Speed Settings

How to adjust blower motor speed for optimal airflow and performance.

Maintenance and Troubleshooting

Drain Connections and Maintenance

Proper drain line installation, checking condensate flow, and routine maintenance.

Coil Cleaning and Lubrication

Procedures for cleaning coils and lubricating blower motor bearings.

Condensate Drains and Troubleshooting

Checking condensate drains for blockages and common troubleshooting issues.

Related product manuals