EasyManua.ls Logo

York N1VSD10A06 User Manual

York N1VSD10A06
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
GENERAL
This instruction covers the installation of the following variable
speed blower sections.
The blower section is the basic component of an indoor modular
system which may be combined with various accessories listed
below to make an evaporator blower, evaporator blower with
electric heat, heat pump blower, and heat pump blower with
electric heat.
Because of the many ways this Air Handler may be applied and
the large variety of available accessories, the indoor portion of the
cooling or heat pump system comes to you in modules. These
modules must be field assembled to meet the specific needs of
the owner.
If this variable speed air handler is installed with a two stage
(H*DS) outdoor condensing unit, a thermal expansion valve kit
must be installed on the indoor side.
Check modules (accessories, etc.) received, against plans to be
sure all required modules are available for assembly.
INSPECTION
As soon as a unit is received, it should be inspected for possible
damage during transit. If damage is evident, the extent of the
damage should be noted on the carrier’s freight bill. A separate
request for inspection by the carrier’s agent should be made in
writing. See Form 50.15-NM for more information.
REFERENCE
This instruction should be used in conjunction with installation
instructions supplied with each accessory as well as the matching
outdoor section.
Installer should pay particular attention to the words: NOTE,
CAUTION and WARNING.
NOTES
are intended to clarify or make the installation easier.
CAUTIONS
are given to prevent equipment damage.
WARNINGS
are given to alert the installer that personal injury
and/or equipment damage may result if installation procedures
are not handled properly.
®
TYPE OF APPLICATIONS
UPFLOW DOWNFLOW
HORIZONTAL
ELECTRIC FURNACE
WITH 018 - 024 COIL
WITH 030 - 061 COIL
*
*Righthand return may be used by remov ing Horizontal Drain Pan
WITH 024 COIL
FIGURE 1 - Typical Component Application
N1VSD10A06
N1VSD14A06
N2VSD20A06
VARIABLE SPEED AIR HANDLERS
FOR USE WITH SPLIT SYSTEM COOLING AND HEAT PUMP
INSTALLATION INSTRUCTION
Supersedes: 535.03-N1Y (1293)
535.03-N1Y (594)
035-10809
N*VS BLOWER SECTIONS
CAUTION
THE ENCLOSED INSTALLATION INSTRUCTIONS AND ANY APPLICABLE
LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED
TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES.
THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH
WARNING
OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY
OR PROPERTY DAMAGE.
INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE
Question and Answer IconNeed help?

Do you have a question about the York N1VSD10A06 and is the answer not in the manual?

York N1VSD10A06 Specifications

General IconGeneral
BrandYork
ModelN1VSD10A06
CategoryAir Handlers
LanguageEnglish

Summary

N*VS BLOWER SECTIONS INSTALLATION

GENERAL INSTALLATION OVERVIEW

Covers installation of variable speed blower sections and their modular assembly.

TYPICAL APPLICATION TYPES

Illustrates typical component applications for upflow, downflow, and horizontal setups.

SAFETY PRECAUTIONS AND WARNINGS

Provides guidance to prevent equipment damage and alerts to potential injury or damage.

INSTALLATION LIMITATIONS AND CLEARANCES

UNIT OPERATIONAL LIMITATIONS

Specifies voltage limits, airflow, and entering air temperature limits.

REQUIRED INSTALLATION CLEARANCES

Details required clearances for piping, servicing, and filter removal.

LOCATION AND DUCTING CONSIDERATIONS

UNIT LOCATION GUIDELINES

Provides guidance on selecting a suitable location for the unit.

DUCT CLEARANCE REQUIREMENTS

Illustrates duct clearance requirements.

INDOOR UNIT PREPARATION AND ACCESSORIES

PREPARING THE INDOOR UNIT FOR INSTALLATION

Outlines steps for preparing the indoor unit for installation.

ACCESSORY INSTALLATION GUIDES

Guidance on installing coil casing, floor base, filter rack, suspension kit, and controls.

ELECTRICAL CONNECTIONS AND DIMENSIONS

POWER WIRING CONNECTIONS

Details power wiring routing and connections for accessories.

UNIT DIMENSIONAL DATA

Provides dimensional data for blower and coil configurations.

POWER SUPPLY AND CONTROL WIRING

LINE POWER SUPPLY CONNECTIONS

Shows single and dual supply line power connections.

ELECTRIC HEAT CONTROL BOARD DIAGRAMS

Diagrams of typical electric heat control boards.

LOW VOLTAGE WIRING AND BLOWER CONTROL

LOW VOLTAGE CONTROL WIRING PROCEDURES

Details low voltage wiring connections to the connector board.

BLOWER SPEED AND AIRFLOW CONTROL

Explains variable speed blower operation and CFM compensation.

AIRFLOW ADJUSTMENTS AND MAINTENANCE

CFM SETTING PROCEDURES

Instructions for setting cooling, heat pump, and electric heat CFM using jumpers.

UNIT MAINTENANCE AND CLEANING

Guidance on cleaning filters and unit coils.

TECHNICAL DATA TABLES

CFM/TAP SELECTION TABLE

Provides CFM selections based on jumper settings for different models.

ELECTRICAL DATA TABLES

Electrical data for transformer and heater accessories.

HEATER ACCESSORY DATA TABLES

HEATER ELECTRICAL DATA AND SPECIFICATIONS

Electrical data for heater accessories, including KW, MBH, wiring, and protection.

CONTROL WIRING DIAGRAMS

TRANSFORMER ACCESSORY WIRING DIAGRAMS

Diagrams for control wiring with transformer accessory for cooling units.

ELECTRIC HEAT CONTROL WIRING

ELECTRIC HEAT COOLING WIRING DIAGRAMS

Diagrams for control wiring with electric heat for cooling units.

HEAT PUMP CONTROL WIRING

ELECTRIC HEAT HEAT PUMP WIRING DIAGRAMS

Diagrams for control wiring with electric heat for heat pump units.

Related product manuals