036-21610-001 Rev. A (0804)
2 Unitary Products Group
3/4
FRONT LEFT SIDE
RIGHT SIDE
GAS INLET
1-1/4" X 2-1/2"
D
(Vent Connection)
5-3/4
2-1/2
ALT. GAS INLET
1-1/4" X 2-1/2"
T'STAT WIRING
7/8" K.O.
31-1/8
28-1/2
20
B
40
A
TOP IMAGE
Vent Connection
(vent size)
D
20
B
BOTTOM IMAGE
1-1/8
20
FRONT
1-1/8
Power
Wiring
7/8" K.O.
A
C
7-3/8
FRONT
E
5
F
1-7/8
CABINET AND DUCT DIMENSIONS
BTUH
Input/Output
CFM
Cabinet
Size
Cabinet Dimension
ABCDEF
40/32 1200 A 14 1/2 13 1/4 10 1/8 4.0 10 1/8 3 3/4
60/48 1200 A 14 1/2 13 1/4 10 1/8 4.0 10 1/8 3 3/4
80/64 1200 A 14 1/2 13 1/4 10 1/8 4.0 10 1/8 3 3/4
80/64 1600 B 17 1/2 16 1/4 13 1/8 4.0 11 5/8 3 3/4
100/80 1200 B 17 1/2 16 1/4 13 1/8 4.0 11 5/8 3 3/4
100/80 2000 C 21 19 3/4 16 5/8 4.0 13 3/8 3 3/4
115/92 1600 C 21 19 3/4 16 5/8 4.0 13 3/8 3 3/4
115/92 2000 C 21 19 3/4 16 5/8 4.0 13 3/8 3 3/4
130/104 2000 D 24 1/2 23 1/4 20 1/8 4.0 15 1/8 3 3/4
HORIZONTAL SIDEWALL VENTING CLEARANCES - MUST USE FIELDS CONTROL MODELS SWG-4Y OR TJERENLAND
MODEL GPAK-JT FIELD SUPPLIED POWER VENTING KITS
Heating Heating Furnace Horizontal Vent Length Ft with 4 Elbows
Input Output Airflow Pipe Size Min. Vent Length Max. Vent Length
BTU/H BTU/H CFM Inches Feet Feet
40,000 32,000 1200 4 4.5 34.5
60,000 48,000 1200 4 4.5 34.5
80,000 64,000 1200 4 4.5 34.5
80,000 64,000 1600 4 4.5 34.5
100,000 80,000 1200 4 4.5 34.5
100,000 80,000 2000 4 4.5 34.5
115,000 92,000 1600 4 4.5 34.5
115,000 92,000 2000 4 4.5 34.5
130,000 104,000 2000 4 4.5 34.5