Electrical Precautions
Takethefollowingprecautionstoreducetheriskofelectricshock,reor
explosionresultinginseriousinjuryordeath.
Highlydangerouselectricalvoltagesareusedinthissystem.Carefullyrefertothewiringdiagram
andtheseinstructionswhenwiring.Improperconnectionsandinadequategroundingcancause
seriousinjuryordeath.
Performallelectricalworkinstrictaccordancewiththisinstallationandmaintenancemanualandall
therelevantregulatorystandards.
Beforeservicing,shutoffandtagalldisconnectswitches.Neverassumeelectricalpoweris
disconnected.Alwaysverifywithameter.
Onlyuseelectricalprotectionequipmentandtoolssuitedforthisinstallation.
Insulateawiredcontrolleragainstmoistureandtemperatureextremes.
Usespeciedcablesbetweenunits.
Theinstalledairconditionermaynotfunctionnormallyinthefollowinginstances:
Ifelectricalpowerforthenewairconditionerissuppliedfromthesametransformerasthe
externalequipment*referredtobelow.
Ifthepowersupplywiringforthisexternalequipment*andthenewairconditionerunitarelocated
incloseproximitytoeachother.
externalequipment*:(Example):Alift,containercrane,rectierforelectricrailway,inverter
powerdevice,arcfurnace,electricfurnace,large-sizedinductionmotorandlarge-sized
switch.
Regardingthecasesmentionedabove,surgevoltagemaybeinductedintothepowersupply
cablesforthepackagedairconditionerduetoarapidchangeinpowerconsumptionofthedevice
andanactivationofaswitch.
Checkeldregulationsandstandardsbeforeperformingelectricalworkinordertoprotectthe
powersupplyforthenewairconditionerunit.
CommunicationcablemustbeaminimumofAWG18(0.82mm
2
),2-Conductor,StrandedCopper.
ShieldedcablemustbeusedforapplicationsandroutinginareasofhighEMIandothersourcesof
potentiallyexcessiveelectricalnoisetoreducethepotentialforcommunicationerrors.Whenshielded
cablingisapplied,properbondingandterminationofthecableshieldisrequiredasperJohnson
Controlsguidelines.Plenumandriserratingsforcommunicationcablesmustbeconsideredper
applicationandlocalcoderequirements.
Thepolarityoftheinputterminalsisimportant,sobesuretomatchthepolaritywhenusingcontacts
thathavepolarity.
Useadedicatedcircuitfortheairconditionerattheunit’sratedvoltage.
Highlydangerouselectricalvoltagesareusedinthissystem.Carefullyrefertothewiringdiagramand
theseinstructionswhenwiring.Improperconnectionsandinadequategroundingcancauseserious
injuryordeath.
Beforeinstallingthecontrollerorremotedevices,ensurethattheindoorandoutdoorunitoperation
hasbeenstopped.Further,besuretowaitatleastveminutesbeforeturningoffthemainpower
switchtotheindoororoutdoorunits.Otherwise,waterleakageorelectricalbreakdownmayresult.
DonotopentheservicecoveroraccesspaneltotheindoororoutdoorunitswithoutturningOFFthe
mainpowersupply.Beforeconnectingorservicingthecontrollerorcablestoindoororoutdoorunits,
shutoffandtagalldisconnectswitches.Neverassumeelectricalpowerisdisconnected.Alwaysverify
withameter.
ThisequipmentcanbeinstalledwithaGroundFaultCircuitBreaker(GFCI),whichisarecognized
measureforaddedprotectiontoaproperlygroundedunit.Installappropriatesizedbreakers/fuses
/overcurrentprotectionswitches,andwiringinaccordancewithlocal,stateandNECcodesand
requirements.Theequipmentinstallerisresponsibleforunderstandingandabidingbyapplicable
codesandrequirements.