571209-YTG-B-1211
Johnson Controls Unitary Products 23
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. YHJD24S41S4
INDOOR COIL MODEL NO. AHP30
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM 600 800 1000
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C. 22.6 25.9 25.9 28.3 29.4 25.2 27.1 26.8 29.2 30.4 27.9 28.3 27.6 30.0 31.4
S.C. 22.6 20.9 18.1 18.1 15.5 25.2 23.9 19.7 19.5 16.1 27.9 26.9 21.3 20.9 16.6
KW 1.6 1.6 1.6 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.8 1.8 1.8 1.8 1.8
75
T.C. 21.5 24.1 24.2 26.6 28.1 23.9 25.3 25.1 27.5 29.0 26.3 26.4 26.0 28.5 29.9
S.C. 21.5 20.1 17.3 17.3 14.7 23.9 22.8 19.1 18.9 15.4 26.3 25.6 20.9 20.6 16.1
KW 1.7 1.8 1.8 1.8 1.8 1.8 1.9 1.8 1.9 1.9 1.9 1.9 1.9 2.0 2.0
85
T.C. 20.4 22.3 22.4 24.8 26.8 22.6 23.4 23.4 25.9 27.6 24.7 24.5 24.4 26.9 28.4
S.C. 20.4 19.4 16.5 16.4 13.8 22.6 21.8 18.6 18.4 14.7 24.7 24.3 20.6 20.3 15.6
KW 1.9 1.9 1.9 1.9 1.9 2.0 2.0 2.0 2.0 2.0 2.1 2.1 2.1 2.1 2.1
95
T.C. 19.4 20.6 20.6 23.0 25.5 21.2 21.6 21.7 24.2 26.2 23.1 22.6 22.7 25.4 26.9
S.C. 19.4 18.6 15.7 15.6 13.0 21.2 20.8 18.0 17.8 14.0 23.1 22.6 20.2 20.0 15.1
KW 2.0 2.0 2.0 2.0 2.1 2.1 2.1 2.1 2.1 2.2 2.2 2.2 2.2 2.3 2.3
105
T.C. 17.6 18.0 18.0 20.9 23.5 19.4 19.5 18.9 21.9 24.3 21.3 21.0 19.9 23.0 25.1
S.C. 17.6 17.2 14.5 14.7 12.0 19.4 19.3 16.7 16.9 13.2 21.3 21.0 18.8 19.1 14.4
KW 2.1 2.1 2.1 2.2 2.2 2.2 2.2 2.2 2.3 2.3 2.3 2.3 2.3 2.4 2.4
115
T.C. 15.8 15.5 15.4 18.8 21.5 17.6 17.5 16.2 19.7 22.4 19.5 19.5 17.0 20.6 23.3
S.C. 15.8 15.5 13.3 13.9 11.1 17.6 17.5 15.3 16.0 12.4 19.5 19.5 17.0 18.2 13.7
KW 2.2 2.2 2.2 2.3 2.4 2.3 2.3 2.3 2.4 2.5 2.5 2.5 2.4 2.5 2.6
125
T.C. 13.9 13.0 12.7 16.6 19.5 15.8 15.5 13.4 17.4 20.5 17.7 17.9 14.1 18.2 21.5
S.C. 13.9 13.0 12.1 13.0 10.1 15.8 15.5 13.4 15.2 11.5 17.7 17.9 14.1 17.3 13.0
KW 2.3 2.2 2.2 2.4 2.5 2.4 2.4 2.4 2.5 2.6 2.6 2.6 2.5 2.6 2.7
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Air Handlers Coils T.C. S.C. KW
– FC/MC/PC32 1.00 1.00 1.04
– FC/MC/PC35 0.99 1.00 1.03
– FC/MC/PC37 1.01 1.01 1.05
– FC/MC/PC43 1.01 1.01 1.05
AHE24B – 0.98 0.99 0.93
AHE30B – 0.98 0.99 0.93
AHR24B – 0.98 0.96 1.02
AHR30B – 0.98 0.96 1.02
AHX30 – 1.01 1.02 0.96
AHX36 – 1.01 1.02 0.96
AV*36 – 1.01 0.99 0.96
F4FP040 – 1.00 1.00 1.04
F6FP030 – 1.01 1.03 0.96
F6FP036 – 1.01 1.03 0.96
MV12B FC/MC35B 1.01 1.02 0.96
MV12B FC/MC43B 1.01 1.01 0.96
MX12B FC/MC35B 0.98 1.00 0.93
MX12B FC/MC43B 0.98 0.97 0.93
Furnaces Coils T.C. S.C. KW
T*(8,L)X*A12 FC/MC/PC32A 1.01 1.02 0.96
T*(8,L)X*B12 FC/MC/PC35B 1.01 1.03 0.96
T*(8,L)X*C16 FC/MC/PC35C 1.01 1.03 0.96
T*(8,L)X*C20 FC/MC/PC35C 1.01 1.03 0.96
T*9X*B12 FC/MC/PC35B 1.01 1.02 0.96
T*9X*C16 FC/MC/PC35C 1.01 1.01 0.96
T*9X*C20 FC/MC/PC35C 1.01 1.03 0.96
T*(8,L)X*A12 FC/MC/PC37A 1.01 1.04 0.96
T*(8,L)X*B12 FC/MC/PC43B 1.01 1.05 0.96
T*(8,L)X*C16 FC/MC/PC43C 1.01 1.05 0.96
T*(8,L)X*C20 FC/MC/PC43C 1.01 1.01 0.96
T*9X*B12 FC/MC/PC43B 1.01 1.01 0.96
T*9X*C16 FC/MC/PC43C 1.01 1.01 0.96
T*9X*C20 FC/MC/PC43C 1.01 1.01 0.96
(Y*LC/T*8V/T*LV)*A12 FC/MC/PC32A 1.01 1.01 0.96
(Y*LC/T*8V/T*LV)*B12 FC/MC/PC35B 1.01 1.01 0.96
(Y*LC/T*8V/T*LV)*C16 FC/MC/PC35C 1.01 1.03 0.96
(Y*LC/T*8V/T*LV)*C20 FC/MC/PC35C 1.01 0.99 0.96
(Y*9C/T*9V)*B12 FC/MC/PC35B 1.01 1.03 0.96
(Y*9C/T*9V)*C16 FC/MC/PC35C 1.01 1.06 0.96
(Y*9C/T*9V)*C20 FC/MC/PC35C 1.01 1.01 0.96
(Y*LC/T*8V/T*LV)*A12 FC/MC/PC37A 1.01 1.01 0.96
(Y*LC/T*8V/T*LV)*B12 FC/MC/PC43B 1.01 1.01 0.96
(Y*LC/T*8V/T*LV)*C16 FC/MC/PC43C 1.01 1.06 0.96
(Y*LC/T*8V/T*LV)*C20 FC/MC/PC43C 1.01 1.01 0.96
(Y*9C/T*9V)*B12 FC/MC/PC43B 1.01 1.01 0.96
(Y*9C/T*9V)*C16 FC/MC/PC43C 1.01 1.01 0.96
(Y*9C/T*9V)*C20 FC/MC/PC43C 1.01 1.06 0.96
Furnaces Coils T.C. S.C. KW