30 Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. YHJD60S41S4
INDOOR COIL MODEL NO. AHX60
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM 1630 1830 2030
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C. 54.6 57.9 58.1 63.9 69.9 56.8 59.2 59.2 65.2 71.2 58.9 60.5 60.3 66.5 72.6
S.C. 54.4 49.3 42.2 42.0 34.7 56.5 52.5 44.2 43.9 35.7 58.6 55.7 46.2 45.9 36.8
KW 3.2 3.2 3.3 3.3 3.4 3.3 3.3 3.3 3.4 3.4 3.4 3.4 3.4 3.5 3.5
75
T.C. 52.6 55.0 55.3 60.7 66.5 54.5 56.1 56.2 61.9 67.6 56.4 57.2 57.1 63.1 68.8
S.C. 52.3 48.2 40.9 40.6 33.1 54.2 51.0 42.9 42.6 34.2 56.1 53.9 44.9 44.6 35.2
KW 3.6 3.6 3.6 3.7 3.7 3.7 3.7 3.7 3.8 3.8 3.8 3.8 3.8 3.9 3.9
85
T.C. 50.5 52.2 52.4 57.5 63.1 52.2 53.0 53.2 58.6 64.0 53.8 53.9 53.9 59.7 65.0
S.C. 50.3 47.0 39.7 39.3 31.6 51.9 49.6 41.7 41.3 32.7 53.6 52.1 43.6 43.3 33.7
KW 4.0 4.0 4.0 4.1 4.1 4.1 4.1 4.1 4.2 4.2 4.2 4.2 4.2 4.2 4.3
95
T.C. 48.5 49.3 49.5 54.3 59.7 49.9 49.9 50.2 55.3 60.4 51.3 50.5 50.8 56.3 61.2
S.C. 48.2 45.9 38.5 38.0 30.1 49.6 48.1 40.4 40.0 31.1 51.0 50.3 42.3 42.0 32.2
KW 4.4 4.4 4.4 4.5 4.5 4.5 4.5 4.5 4.5 4.6 4.6 4.6 4.6 4.6 4.7
105
T.C. 45.8 45.9 46.0 50.6 55.7 47.1 47.0 46.5 51.4 56.4 48.5 48.1 47.1 52.1 57.0
S.C. 45.6 44.1 37.0 36.5 28.6 46.9 45.9 38.9 38.5 29.6 48.2 47.8 40.9 40.4 30.7
KW 4.9 4.9 4.9 4.9 5.0 5.0 5.0 5.0 5.0 5.1 5.1 5.1 5.1 5.1 5.2
115
T.C. 43.2 42.5 42.4 46.9 51.7 44.4 44.0 42.9 47.4 52.3 45.7 45.6 43.4 48.0 52.9
S.C. 43.0 42.3 35.5 35.1 27.0 44.2 43.8 37.4 37.0 28.1 45.5 45.4 39.4 38.9 29.2
KW 5.4 5.4 5.4 5.4 5.5 5.5 5.5 5.4 5.5 5.6 5.6 5.5 5.5 5.6 5.6
125
T.C. 40.5 39.1 38.8 43.1 47.7 41.7 41.1 39.3 43.5 48.2 42.9 43.1 39.8 43.8 48.7
S.C. 40.3 39.1 34.0 33.6 25.5 41.5 41.1 36.0 35.4 26.6 42.7 42.9 38.0 37.3 27.7
KW 5.9 5.8 5.8 5.9 6.0 5.9 5.9 5.9 6.0 6.0 6.0 6.0 6.0 6.1 6.1
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Air Handlers Coils T.C. S.C. KW
– FC/MC62 1.00 0.99 1.08
– FC64 1.02 1.02 1.10
AHE60D – 1.00 1.00 1.00
F6FP060 – 1.02 1.02 1.01
MX20D FC/MC62D 1.00 1.00 0.99
MX20D FC64D 1.02 1.04 1.01
MV20D FC/MC62D 1.01 1.00 1.04
MV20D FC64D 1.02 1.02 1.01
MA20D FC/MC62D 1.00 0.99 1.08
MA20D FC64D 1.02 1.02 1.10
Furnaces Coils T.C. S.C. KW
T*(8,L)X*C20 FC/MC62D 1.00 0.98 0.99
T*9X*C20 FC/MC62D 1.00 0.95 0.99
T*9X*D20 FC/MC62D 1.00 0.96 0.99
T*(8,L)X*C20 FC64D 1.02 1.00 1.01
T*9X*C20 FC64D 1.02 0.98 1.01
T*9X*D20 FC64D 1.02 0.99 1.01
(Y*LC/T*8V/T*LV)*C20 FC/MC62D 0.99 0.95 0.98
(Y*9C/T*9V)*C20 FC/MC62D 0.99 0.95 1.02
(Y*9C/T*9V)*D20 FC/MC62D 0.99 0.95 1.02
(Y*LC/T*8V/T*LV)*C20 FC64D 1.01 0.99 1.00
(Y*9C/T*9V)*C20 FC64D 1.01 0.99 1.04
(Y*9C/T*9V)*D20 FC64D 1.01 0.98 1.04