Yudian AI-516 - Run, Hold, and Stop Operations

Default Icon
33 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
then can press , or to adjust value. Press key to decrease the value, key
to increase the value, and key to move to the digit expected to modify. Keep pressing
or , the speed of decreasing or inscreasing value get quick. The range of setpoint is
between the parameter SPL and SPH. The default range is 0~400.
Program segment setting:
Press the key once and release in the display status, the instrument will be in the setup
program status.
set point of the current program StEP will be displayed.
Pressing
or can modify the value.
Pressing can go to next parameter. The program parameters will be displayed in the
sequence
setpoint1, time1, setpoint2, time2.
Pressing and holding for about 2 seconds will return to the previous parameter. Program step
can modify
anytime even the program still in running.
Run / Hold only (for AI-516P)
In basic display status, if the program is in stoP status (
StoP
is alternately displayed on the lower
window),and hold the key for about 2 seconds until the lower display window displays the
"Run" symbol,instrument then will start the program.
If parameter PAF set F=1, user can hold the key for about 2 seconds, instrument will
changes tostatus and lower display window displays the "HoLd" symbol. If parameter
PAF
set
F=0,
Hold
status onlyactivate by parameter setting (Srun).
At Hold status, the program is still executing, and the process value is controlled same as setpoint,
but thestop working, and the running time and setpoint remains. At Hold status, press and hold the
key for aboutseconds until the lower display window displays the "Run" symbol, the
instrument will back to run program
Stop
Press and hold the key for about 2 seconds in the basic display status, until the lower
display window displays the "stoP" symbol, means the stoP operation is executed now, when
program stopped, timer will be reset and stop. This operation forces the instrument to stop running,
meanwhile, the StEP number will reset to 1, and control output is also stopped