INSTALLATION,
OPERATION
&
MAINTENANCE
MANUAL
SINGLE PACKAGED ROOF TOP AIR CONDITIONERS
'PS' SERIES
MODELS: PS036 - PS360
Part Number: 800-213-04

Questions and Answers

  • J
    jtorresSep 8, 2025
    What causes Zamil Air Conditioner blower to delivers excess air?
    • K
      Karen KnoxSep 8, 2025
      If your Zamil Air Conditioner's blower is running and delivering too much air, it could be due to: * **Variable Pulley:** The variable pulley might need tightening. Adjust the pitch of the pulley. * **Improper Pulley/Motor Selection:** The pulley or motor selection might be unsuitable. Select a suitable combination. * **Low External Static Pressure:** The external static pressure might be low. Check the duct design.
  • C
    Chase MclaughlinAug 22, 2025
    How to fix Zamil Air Conditioner thermostat with no display?
    • J
      Jeff FoxAug 22, 2025
      If your Zamil Air Conditioner's thermostat shows no display, here's what you can check: * **Power:** Make sure the unit is receiving power by checking the circuit breaker and switching it ON. Replace the fuse if it's blown. * **Wiring:** Inspect the field wiring against the wiring diagram to ensure it's correctly connected. * **Connections:** Look for any loose connections and correct them. * **Thermostat:** If none of the above steps work, the thermostat itself might be defective and need replacement.
  • R
    Rachel DillonSep 5, 2025
    Why Zamil Air Conditioner thermostat LCD panel display is not bright?
    • J
      Jeffrey ThomasSep 5, 2025
      If the thermostat LCD panel display of your Zamil Air Conditioner is not bright and doesn't function properly, it's likely that the battery life is over. Replace the battery.
  • A
    Ashley MuellerSep 3, 2025
    What to do if Zamil Air Conditioner blower not running, compressor short cycles?
    • V
      Valerie LawrenceSep 4, 2025
      If your Zamil Air Conditioner is running but the blower isn't, and the compressor is short cycling, here's what to investigate: * **Blower Belt:** Ensure the blower belt is correctly placed and not slipped. Check its tension and alignment. * **Wiring:** Inspect the wiring against the diagram for any faults. * **Burned Wiring:** Check for and correct any burned wiring. * **Blower Motor Contactor:** If defective, replace the blower motor contactor. * **Blower Motor:** If the blower motor is defective, replace it.
  • M
    Michael JonesSep 2, 2025
    Why does the circuit breaker of my Zamil Air Conditioner keep tripping?
    • M
      marshallanaSep 2, 2025
      If your Zamil Air Conditioner's circuit breaker trips, it could be due to: * **Burned Wiring:** Inspect and correct any burned wiring. * **Grounded Wiring:** Perform a megger test to check for grounded wiring. * **Faulty Field Wiring:** Check the field wiring against the wiring diagram. * **Grounded Motor:** If the compressor or blower motor is grounded, replace it if necessary. * **Undersized Breaker:** Verify that the circuit breaker has the correct ratings.
  • B
    Bernard HarrisSep 1, 2025
    Why is my Zamil Air Conditioner so noisy?
    • D
      Danny WeaverSep 1, 2025
      If your Zamil Air Conditioner is making excessive noise, here are some potential causes and solutions: * **Improper Installation:** Check the installation and correct it properly. * **Improper Vibration Isolators:** Check the vibration isolators and correct them properly. * **Loose Parts or Mountings:** Check for loose parts or mountings and tighten them. * **Tubing Rattle:** Tighten the pipe support to prevent tubing rattle. * **Bent Fan Blade:** Check the balance, alignment, and bracket of the fan blade. Correct or replace it if necessary. * **Defective Bearings:** Replace the motor if the bearings are defective. * **High Belt Tension:** Adjust the belt tension. * **Misaligned Blower Motor Pulley:** Align the blower motor pulley.
  • N
    Nathan MorganAug 30, 2025
    Why is my Zamil Air Conditioner running but not cooling enough?
    • O
      olivia62Aug 30, 2025
      If your Zamil Air Conditioner is running continuously but not cooling sufficiently, consider these factors: * **Low Suction Pressure:** Verify the reason for the low suction pressure and correct it. * **High Discharge Pressure:** Verify the reason for the high discharge pressure and adjust the Freon if required. * **Less Air Quantity:** Check for insufficient air quantity. * **Cooling Coil Icing:** Determine the reason for the cooling coil icing up and correct it. * **Second Stage (if applicable):** If a second stage exists, set the thermostat to a lower temperature (21°C) or verify the reason it's not working. * **Serving Large Area:** The unit might be serving too large of an area; check the design.
  • J
    James GarciaAug 29, 2025
    Why is the cooling coil ices up in my Zamil Air Conditioner?
    • J
      julia05Aug 29, 2025
      If your Zamil Air Conditioner's cooling coil is icing up, here's what could be happening: * **Less Freon:** There might be a Freon leak. Check for leaks and charge Freon as required. * **Less Air Quantity:** There might be insufficient air quantity. Determine the reason and correct it. * **Dirty Filter:** The filter might be dirty. Clean it. * **Dirty Cooling Coil:** The cooling coil itself might be dirty. Clean it.
  • S
    stephen76Aug 27, 2025
    What causes Zamil Air Conditioner compressor not working?
    • C
      Christopher RobertsAug 27, 2025
      If your Zamil Air Conditioner's compressor is not working, consider the following potential causes: * **Low Voltage:** The voltage might be too low. Rectify the reason and correct it. * **Single Phase Failure:** There might be a single-phase failure. Check the compressor amperage for each phase. * **Burned Wiring:** The wiring might be burned. Check and correct it. * **Overload Protector:** The overload protector might be open. Check and verify the reason. * **Defective Contactor:** The contactor might be defective. Check and replace it. * **Burned Compressor Motor Winding:** The compressor motor winding might be burned. Check and replace it. * **Damaged Compressor:** The compressor might be damaged or stuck. Check and replace it.
  • J
    Joshua GarciaAug 27, 2025
    Why is my Zamil Air Conditioner not sufficiently cooling during daytime?
    • N
      Nicholas PatelAug 27, 2025
      If your Zamil Air Conditioner unit is not cooling properly during the daytime, here are a few things to check: * **High Discharge Pressure:** Verify the reason for high discharge pressure. * **Thermostat Setting:** Ensure the thermostat is set correctly; adjust it if needed. * **Serving Area:** The unit might be serving too large of an area; check the design and unit selection. * **Less Air Quantity:** Verify the reason for insufficient air quantity. * **High Ambient Condition:** Check the ambient conditions. * **Dirty Condenser:** Clean the condenser.

Summary

Model Decoding

PS036 - PS060 Direct Drive Motor Models

Decoding guide for PS036-PS060 models with direct drive motors.

PS075 - PS360 Belt Driven Motor Models

Decoding guide for PS075-PS360 models with belt driven motors.

General Information

General Statement

Overview of the unit's design and recommended practices for operation.

Warranty Information

Details on manufacturer warranty terms and coverage for PS series units.

Safety Issues and Precautions

Identifies safety hazards (WARNING, CAUTION) and essential safety measures.

Inspection for Damage

Procedure for visually inspecting the unit for physical damage upon delivery.

Installation Instructions

Location of Unit

Guidelines for selecting an appropriate installation site for the unit.

Service Clearance Requirements

Minimum clearances needed around the unit for service access and airflow.

Rigging Instructions

Procedures and precautions for safely rigging and moving the unit.

Condensate Drain Connection

Instructions for connecting the condensate drain piping.

Duct Connection

Guidelines for properly connecting the unit to the ductwork system.

Electric Heaters

Information regarding the electric heater kit installation.

Cable Size Requirements

Guidance on selecting appropriate cable sizes for electrical connections.

Unit Weight and Distribution

Details on unit weight and its distribution for installation planning.

Unit Dimensions

PS036 - PS075 Dimensions

Physical dimensions for PS036 through PS075 models.

PS090 - PS120 Dimensions

Physical dimensions for PS090 through PS120 models.

PS180 Dimensions

Physical dimensions for the PS180 model.

PS215 - PS240 Dimensions

Physical dimensions for PS215 through PS240 models.

PS300 - PS360 Dimensions

Physical dimensions for PS300 through PS360 models.

Operation Instructions

Start-Up, Inspection & Check List

Pre-operation checks and steps for system start-up.

Performex-1 T Controller Functions

Features and operations of the Performex-1T™ controller.

Electronic Thermostat Operation

How to use and set the electronic thermostat for unit control.

Crankcase Heater Operation

Guidelines for operating and checking the crankcase heater.

Pump Down Control Operation

Explanation of the pump down system and its control.

Maintenance Instructions

Airflow Adjustment

Procedure for adjusting unit airflow via pulleys or belt tension.

Crankcase Heater Maintenance

Recommended checks for the proper operation of the crankcase heater.

Cleaning of Coils & Filters

Steps for cleaning evaporator coils, condenser coils, and filters.

Belt Tension Testing Procedure

Method for testing and adjusting drive belt tension.

Electrical Data

Models: PS036 & PS048 Electrical Data

Electrical specifications for PS036 and PS048 models.

Models: PS060 & PS075 Electrical Data

Electrical specifications for PS060 and PS075 models.

Models: PS090 & PS100 Electrical Data

Electrical specifications for PS090 and PS100 models.

Models: PS120 & PS180 Electrical Data

Electrical specifications for PS120 and PS180 models.

Models: PS215 & PS240 Electrical Data

Electrical specifications for PS215 and PS240 models.

Models: PS300 & PS360 Electrical Data

Electrical specifications for PS300 and PS360 models.

Trouble Shooting Chart

Typical Schematic Wiring Diagrams

PS036 - PS075 (208;230 V)

Wiring diagram for PS036-PS075 models, 208/230V supply.

PS036 - PS075 (380 V)

Wiring diagram for PS036-PS075 models, 380V supply.

PS036 - PS075 (460 V)

Wiring diagram for PS036-PS075 models, 460V supply.

PS090 - PS120 (208;230 V)

Wiring diagram for PS090-PS120 models, 208/230V supply.

PS090 - PS120 (380 V)

Wiring diagram for PS090-PS120 models, 380V supply.

PS090 - PS120 (460 V)

Wiring diagram for PS090-PS120 models, 460V supply.

PS180 - PS240 (208;230 V)

Wiring diagram for PS180-PS240 models, 208/230V supply.

PS180 - PS240 (380 V)

Wiring diagram for PS180-PS240 models, 380V supply.

PS180 - PS240 (460 V)

Wiring diagram for PS180-PS240 models, 460V supply.

PS300 - PS360 (208;230 V)

Wiring diagram for PS300-PS360 models, 208/230V supply.

PS300 - PS360 (380 V)

Wiring diagram for PS300-PS360 models, 380V supply.

PS300 - PS360 (460 V)

Wiring diagram for PS300-PS360 models, 460V supply.

Parts List

Zamil PS360 Specifications

General IconGeneral
BrandZamil
ModelPS360
CategoryAir Conditioner
LanguageEnglish

Related product manuals