AF6ZP0AL - COMBIAC0 & ACE0 - User Manual Page - 49/79
- ON +VB = When it is closed to a battery (key) voltage, the Backward
Travel demand is Active.
- OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND), the Backward Travel demand is not active.
21) DI5/HORN SWITCH
ON/OFF. This is the level of the digital CNA#19:
- ON +VB = When it is closed to a battery (key) voltage the HORN request
is active.
- OFF GND = When it is not closed to a battery (key) voltage (or
connected to GND) the HORN request is not active.
22) DI6/BELLY SWITCH
ON/OFF. This is the level of the digital input CNA#7 ( belly button):
- ON +VB = When it is closed to a battery (key) voltage, the request of the
Belly (to stop the movement) is active.
- OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND), the Belly request is not active.
23) DI7/LIFT SWITCH
ON/OFF. This is the level of the digital input CNA#35:
- ON +VB = When it is closed to a battery (key) voltage the voltage the
LIFTING request is active.
- OFF GND = When it is not closed to a battery (key) voltage (or
connected to GND) the voltage the LIFTING request is not active.
24) DI8 / BACKING FOR
ON/OFF. This is the level of the digital input CNA#17 for the inching forward
request:
- ON +VB = When it is closed to a battery (key) voltage the forward
inching demand is active.
- OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND) the forward inching demand is not active.
25) DI9/ H&S SWITCH [H&S FUNCTION option PRESENT]
ON/OFF. This is the level of the digital input CNA#29 for the Hard & Soft
request. With the H&S service is possible to turn the truck moving (at
reduced speed) only by acting the H&S switch, and the accelerator, without
to let down the tiller :
- ON +VB = When it is closed to a battery (key) voltage, the H&S request
is Active.
- OFF GND = When it is not connected to a battery (key) voltage (or it is
connected to GND), the H&S request is not active.
26) DI9/CUTBACK SWITCH 2 [H&S FUNCTION option ABSENT]
ON/OFF. This is the level of the digital input CNA#29:
- ON GND = When it is not closed to a battery (key) voltage (or connected
to GND) the CUTBACK2 request is active.
- OFF +VB = When it is closed to a battery (key) voltage the CUTBACK2
request is not active
27) DI10 / BACKING REV
ON/OFF. This is the level of the digital input CNA#16 for the inching reverse
request:
- ON +VB = When it is closed to a battery (key) voltage, the reverse