Mobile Printer CPCLProgramming Manual P10-29
NTN:This options disables the reporting
of the track number, inserted between
the delimiters. The printer enables track
number reporting by default.
Error Reporting Options
ERRORS: This option turns error reporting on.
Error reporting is turned off by default.
The following is a list of the error mes-
sages (Please note that the following
error messages will be transmitted only
if error reporting is turned on, via the
ERRORS option in the MCR command):
READ ERROR: This error is reported
when the card could not be read due to
errors such as parity check, LRC check-
sum, no end-sentinel, or invalid charac-
ters. It indicates that either: (1) the card
is bad, or (2) the card was not swiped
correctly. The printer will leave the MCR
on and will continue to try to read future
card swipe retries by the user until it
times out or until a successful read,
whichever occurs first.
CANCEL: This error is reported when a
MCR-CAN command is received. This
error message will confirm that the MCR
is turned off.
TIME-OUT: This error is reported when
the printer MCR times out before a
successful read.