Mobile Printer CPCLProgramming Manual P14-35
power.low_battery_shutdown
type: getvar
This parameter refers to the low battery shutdown level.
getvar result Current low-battery shutdown level in volts.
Example Description Get current low-battery shutdown
level.
Syntax ! U1 getvar
“power.low_battery_shutdown”
Result “6.47(166)”
power.low_battery_warning
type: getvar
This parameter refers to the low battery warning level.
getvar result Current low-battery warning level in volts.
Example Description Get current low-battery warning
level.
Syntax ! U1 getvar
“power.low_battery_warning”
Result “6.86(176)”
power.percent_full
type: getvar
This parameter refers to the battery status.
getvar result Battery status as percent full.
Example Description Get current battery status.
Syntax ! U1 getvar “power.percent_full”
Result “ 43% Full”
power.status
type: getvar
This parameter refers to the battery status.
getvar result “ok”, “low”
Example Description Get current battery status.
Syntax ! U1 getvar “power.status”
Result “ok”