2EADALL)NSTRUCTIONSBEFORE)NSTALLINGANDOPERATINGTHISAPPLIANCE
-/$%,AK2000,AK6000,AK9800
)MPORTANT3AFETY.OTICE
5SE#AREAND)NSTALLATION'UIDE
:$51,1*
725('8&(7+(5,6.2)),5(25(/(&75,&6+2&.'212786(7+,6
)$1:,7+$1<62/,'67$7(&21752/'(9,&(
:$51,1*
725('8&(7+(5,6.2)),5((/(&75,&6+2&.25,1-85<72
3(562162%6(59(7+()2//2:,1*
D8VHWKLVXQLWRQO\LQWKHPDQQHULQWHQGHGE\WKHPDQXIDFWXUHULI\RXKDYHTXHVWLRQV
FRQWDFWWKHPDQXIDFWXUHU
E%HIRUHVHUYLFLQJRUFOHDQLQJXQLWVZLWFKSRZHURIIDWVHUYLFHSDQHODQGORFNSDQHO
WRSUHYHQWSRZHUIURPEHLQJVZLWFKHGRQDFFLGHQWDOO\:KHQWKHVHUYLFHGLVFRQQHFWLQJ
PHDQVFDQQRWEHORFNHGVHFXUHO\IDVWHQDSURPLQHQWZDUQLQJGHYLFHVXFKDVDWDJ
WRWKHVHUYLFHSDQHO
&$87,21
)RUJHQHUDOYHQWLODWLQJXVHRQO\'RQRWXVHWRH[KDXVWKD]DUGRXVRUH[SORVLYHPDWHULDOV
DQGYDSRUV7DNHFDUHZKHQXVLQJFOHDQLQJDJHQWVRUGHWHUJHQWV
6XLWDEOHIRUXVHLQKRXVHKROGFRRNLQJDUHD
:$51,1*
725('8&(7+(5,6.2)5$1*(723*5($6(),5(
D1HYHUOHDYHVXUIDFHXQLWVXQDWWHQGHGDWKLJKVHWWLQJV%RLORYHUVFDXVHVPRNLQJ
DQGJUHDV\VSLOORYHUVWKDWPD\LJQLWH+HDWRLOVVORZO\RQORZRUPHGLXPVHWWLQJV
E$OZD\VWXUQKRRG21ZKHQFRRNLQJDWKLJKKHDWRUZKHQIODPLQJIRRG
F&OHDQYHQWLODWLQJIDQVIUHTXHQWO
\
*UHDVHVKRXOGQRWEHDOORZHGWRDFFXPXODWH
RQIDQRUILOWHU
G8VHSURSHUSDQVL]H$OZD\VXVHFRRNZDUHDSSURSULDWHIRUWKHVL]HRIWKHVXUIDFH
HOHPHQW
H.HHSIDQILOWHUVDQGJUHDVHODGHQVXUIDFHVFOHDQ
I8VHKLJKVHWWLQJRQKRRGRQO\ZKHQQHFHVVDU\
J'RQ¶WOHDYHKRRGXQDWWHQGHGZKHQFRRNLQJ
K$OZD\VXVHFRRNZDUHDQGXWHQVLOVDSSURSULDWHIRUWKHW\SHRIDQGDPRXQWRIIRRG
EHLQJSUHSDUHG
:$51,1*
725('8&(7+(5,6.2),1-85<723(56216,17+((9(172)$5$1*(723
),5(2%6(59(7+()2//2:,1*
D 6027+(5)/$0(6ZLWKDFORVHILWWLQJOLGFRRNLHVKHHWRUPHWDOWUD\WKHQ
WXUQRIIWKHEXUQHU%(&$5()8/7235(9(17%8516,IWKHIODPHVGRQRWJRRXW
LPPHGLDWHO\(9$&8$7($1'&$//7+(),5('(3$570(17
E 1(9(53,&.83$)/$0,1*3$1±<RXPD\EHEXUQHG
F '212786(:$7(5LQFOXGLQJZHWGLVKFORWKVRUWRZHOV±DYLROHQWVWHDP
H[SORVLRQZLOOUHVXOW
5HY ZZZ]HSK\URQOLQHFRP
2%!$!.$3!6%4(%3%).3425#4)/.3

Questions and Answers

  • L
    Linda LucasSep 4, 2025
    What to do if something is loose inside my Zephyr AK6000?
    • N
      Nicole CarpenterSep 4, 2025
      If something seems loose and spinning inside your Zephyr Ventilation Hood when the blowers are on, there might be foreign particles in the discharge opening, such as rocks, leaves, or branches from old duct work. Disconnect the duct work to inspect and remove any foreign particles.
  • C
    cervantesericaSep 18, 2025
    What to do if something seems to be loose and spinning around inside Zephyr AK6000?
    • S
      suzannesimsSep 18, 2025
      If something seems loose and spinning inside your Zephyr Ventilation Hood when the blowers are on, there might be foreign particles in the discharge opening, or debris that fell in from old ductwork. Disconnect the ductwork to inspect and remove any foreign particles.
  • J
    jonathan32Sep 16, 2025
    What to do if light is on but blowers are not turning at all or seems to be scraping on something in Zephyr AK6000 Ventilation Hood?
    • J
      Jesse AndersonSep 16, 2025
      If the light is on but the blowers aren't turning or seem to be scraping in your Zephyr Ventilation Hood, the blower blade unit might be mounted too low. Loosen the hex screw on the blade unit and adjust it to the proper height.
  • J
    jeremyperkinsSep 14, 2025
    Why is my Zephyr AK6000 Ventilation Hood blower so noisy?
    • B
      Brian CooleySep 14, 2025
      If the blowers in your Zephyr Ventilation Hood are making noise, remember they're designed to perform up to 695 cfm. Use both blowers at maximum speed only when needed for heavy cooking like pan-frying or wok cooking. For moderate cooking, use low speeds or a single blower.
  • M
    Michael FrankSep 12, 2025
    Why do the blowers seemed weak in my Zephyr AK6000?
    • S
      Sean SpencerSep 12, 2025
      If the blowers in your Zephyr Ventilation Hood seem weak, check the duct size. It should be at least 6 inches or 3 1/4 x 10 inches. The range hood will not function correctly with an insufficient duct size.
  • R
    Richard HernandezSep 12, 2025
    Why does cooking fumes and smoke dissipates before it reaches the blower of my Zephyr AK6000?
    • S
      scottgarySep 12, 2025
      If cooking fumes and smoke dissipate before reaching the blower of your Zephyr Ventilation Hood, verify that the unit is installed at the recommended height. Also, ensure the blowers are set to high speed, especially during heavy cooking.
  • C
    christophervasquezSep 9, 2025
    Why is no grease collected in the residue containers after self-cleaning my Zephyr AK6000?
    • P
      Patrick Gonzalez DVMSep 9, 2025
      It's normal for no grease to be collected in the residue containers of your Zephyr Ventilation Hood until the self-clean function is completed. Clean blowers approximately once a month as instructed to avoid clogging.
  • F
    fdelgadoSep 7, 2025
    Why is no grease collected in the residue containers of my Zephyr AK6000?
    • J
      James BowmanSep 7, 2025
      Grease flow in your Zephyr Ventilation Hood varies by the amount, methods, and types of cooking. Frequent pan-frying with steaming can help grease flow into the containers, as vapor from steam will liquefy accumulated grease in its internal housing.
  • A
    Allison ReedSep 5, 2025
    What to do if the light is on but blowers are not turning on my Zephyr AK6000 Ventilation Hood?
    • M
      Mathew MuellerSep 5, 2025
      If the light is on but the blowers aren't turning or seem to be scraping in your Zephyr Ventilation Hood, the blower blade unit might be mounted too low and scraping the bottom or jammed. Loosen the hex screw on the blade unit and adjust it to the proper height.
  • K
    Kelly MooreAug 21, 2025
    What to do if my Zephyr AK6000 light is not working?
    • K
      kgriffinAug 21, 2025
      If the light in your Zephyr Ventilation Hood isn't working, the light bulb might need replacement. Sometimes, the bulb gets damaged during shipping. Replace it with a 40 or 60W appliance bulb.

Summary

Important Safety Notice

General Safety Instructions

Follow manufacturer's instructions, ensure proper electrical safety, and use the unit as intended.

Range Top Grease Fire Prevention

Avoid high heat unattended, clean filters, use correct pan size, and turn hood on during high heat cooking.

Grease Fire Response

Smother flames with a lid, avoid water, and evacuate if fire is uncontrollable.

Electrical and Installation Precautions

Ensure qualified installation, proper wiring, use GFCI protection for tub/shower installations.

Ducting and Ventilation Safety

Use metal ductwork and vent exhaust outdoors only; avoid venting into walls or enclosed spaces.

Operational Safety Guards

Keep safety grills and filters in place to prevent contact with moving blower parts.

Product Overview

Hurricane Series Models

Overview of Hurricane series features, including QuattroVent Air Curtain and digital controls.

Cyclone Series Models

Overview of Cyclone series features, including self-clean blowers and convertible ducting.

Whirlwind Series Models

Overview of Whirlwind series features, including slim line design and independent controls.

Key Product Components

Identification of main parts like QuattroVent Air Curtain, blowers, controls, residue cup, and splash guard.

Controls

Hurricane Series Control Functions

Detailed explanation of the digital display, setting time, and light operations.

Blower Operation and Speed Selection

How to turn on/off individual blowers and select speeds (High/Low) using fan buttons.

Timed Delay Off Feature

Setting the auto shut-off timer for blowers at 3, 5, or 10-minute intervals.

Timer (Alarm) Function

Instructions for setting a timer countdown that triggers an alarm upon completion.

Cyclone and Whirlwind Rocker Controls

Operation of rocker switches for light and independent blower control (Hi/Lo/Off).

Maintenance

Self Clean System Description

Explanation of the self-cleaning feature that liquefies grease and collects it.

Cleaning Schedule and Supplies

Recommended cleaning frequency (monthly) and suitable detergents for grease cutting.

Safety Grill Cleaning Procedure

Steps for removing and cleaning safety grills, including necessary precautions.

Self-Clean Cycle Execution

How to initiate the self-clean cycle, including setting a delay timer.

Residue Container Maintenance

Instructions for removing and cleaning the grease residue containers.

Light Shield Cleaning and Replacement

Procedures for cleaning light shields and replacing light bulbs, with safety notes.

Installation

Installation Requirements and Warnings

Emphasizes professional installation, adherence to codes, and electrical safety.

Duct Size and Cut Out Dimensions

Specifies required duct sizes and provides cut-out dimensions for cabinet openings.

Installation Clearance Guidelines

Recommended minimum and maximum clearances above the cooking surface for efficient operation.

Appliance Mounting and Wiring Steps

Detailed, step-by-step instructions for physically installing the range hood and connecting electrical wiring.

Convertible Ducting Options and Adapters

Guide to converting the appliance for different ducting types using provided accessories.

Rear Discharge Installation Procedures

Specific steps for configuring the appliance for a 3-1/4 x 10" rear discharge duct.

Installation Notes

Damper and Starting Collar Installation

Guidance on installing optional dampers and provided starting collars for proper ventilation.

Hood Leveling and Front Tilt Adjustment

How to ensure the hood is level or slightly tilted upwards for optimal grease flow.

Electrical Connection Requirements

Notes on using electrical connectors as required by local codes for secure wiring.

Troubleshooting

Power and Basic Operation Checks

Verifies power, wiring connections, and proper function of lights and blowers.

Noise, Vibration, and Foreign Objects

Addresses causes of unusual noise, vibration, and foreign particles affecting blower operation.

Grease Flow and Blower Performance Issues

Troubleshooting lack of grease collection, weak airflow, and ducting restrictions.

Fume Dissipation and Airflow Optimization

Tips for improving capture of cooking fumes, including installation height and fan speed.

Warranty Information

Warranty Service Procedure

Steps to obtain warranty service, including required documentation and contact details.

Warranty Coverage and Exclusions

Details what parts and labor are covered under the warranty and what is excluded.

Conditions That Void Warranty

Lists actions or circumstances that will render the product warranty invalid.

Zephyr AK6000 Specifications

General IconGeneral
BrandZephyr
ModelAK6000
CategoryVentilation Hood
LanguageEnglish

Related product manuals