13
ACT Conversion
ALUÀRZ&RQWURO7HFKQRORJ\$&7
Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the
PD[LPXPEORZHU&)0RIVHOHFW=HSK\U9HQWLODWLRQUDQJHKRRGVZLWKRXWWKHQHHGIRUH[SHQVLYHPDNHXSDLUNLWV
$&7HQDEOHVWKHLQVWDOOHUWRHDVLO\VHWWKHPD[LPXPEORZHUVSHHGWRRQHRIWZRPRVWFRPPRQO\VSHFL¿HG&)0
OHYHOVRU&)07KHXVDJHRI$&7PD\QRWEHQHFHVVDU\IRU\RXULQVWDOODWLRQ3OHDVHFKHFN\RXUORFDO
codes for CFM restrictions.
By default the maximum blower CFM is set to 1200.
To enable ACT
1. Before hood installation, gain access to PC board by following the steps shown in FIG. C.
2. Change plastic jumper positioning as shown in FIG. D to set the desired maximum blower CFM.
3. Re-install PC board & continue with hood installation.
5HPRYHWKHDSSURSULDWHIRLO&)0VWLFNHULQFOXGHGZLWKWKHKRRGOLWHUDWXUHDQGSODFHLQVLGHWKHKRRGERG\EHORZ
the wiring diagram or in another clearly visible location.
NOTE: After re-positioning the jumper and powering on the hood, the CFM cannot be changed again.
To verify if your installer enabled ACT
:LWKKRRGRႇSUHVVDQGKROGWKHSRZHUEXWWRQIRUWKUHHVHFRQGV,I/('VLOOXPLQDWH GHIXDOWPD[&)0LI
/('VLOOXPLQDWH PD[&)0DQGLI/('VLOOXPLQDWH PD[&)0
:KHQ$&7LVHQDEOHGWKHQXPEHURIEORZHUVSHHGVZLOOEHUHGXFHG&)0 PD[VSHHGVDQG&)0 
max. 2 speeds.
There should also be a foil label located inside the hood body near the wiring diagram that indicates the blower
CFM.
PC Board
1
3
5
7
2
4
6
8
Jumper 5-6 or 7-8
DEFAULT POSITION
Default Max. Blower CFM
Jumper 3-4
Max. Blower CFM
590
Jumper 1-2
Jumper Pins
Plastic
Jumper
1
3
5
7
2
4
6
8
1
3
5
7
2
4
6
8
1
3
5
7
2
4
6
8
Max. Blower CFM
390
CAUTION:
Hood must be disconnected from main power prior to performing the
conversion instructions listed below. Failure to do so could result in
personal injury or damage to the product.
!
- PC Board is located behind internal cover panel.
5HPRYHEDႉH¿OWHUV
- Remove 3 screws attaching internal cover panel.
- Pull down on panel to access PC Board.
FIG. C FIG. D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zephyr Siena Pro ZSP-E36BS and is the answer not in the manual?

Zephyr Siena Pro ZSP-E36BS Specifications

General IconGeneral
Colorstainless steel
Hood Typewall
Venting Typeducted, external
Temperature Sensorno
Number of Fan Speeds5
Duct Diameter10 inches
Duct Length14 1/2 inches
Control Typebutton
Delay Startyes
Interior Lightyes
Remote Controlno
Voltage120 volts
Current9 amperes
Weight and Dimensions IconWeight and Dimensions
Depth21 15/16 inches
Height27 1/2 inches
Width35 7/8 inches
Net Weight62 pounds