ADJUSTMENT
F_02_129 FH12N011 FH12N012
CALIBRATION OF TRAVEL SPEED OF
DIGITAL DASHBOARD
Dashboard is calibrated after the assem-
bly at the production plant.
Do the repeated calibration:
After significant wear of tyres
When mounting new tyres
When replacing dashboard
CALIBRATION PROCEDURE
Mark a track of 100 m at a suitable lo-
cation
Inflate the tyres of the tractor to pre-
scribed pressure, see tables of this In-
structions manual
Start the engine
Bring the tractor to the beginning of the
100-metre track
Press button (A) and button (B) simul-
taneously. Keep the buttons pressed
down for 7 sec. There will be a sound
signal and on the display a sign will be
displayed “Road Constant” / “Self
Learning
Release both buttons (A) and (B
Start driving the tractor at a constant
speed of approximately 10 km.h
-1
After travelling the entire distance of
100 m, stop the tractor at a designated
end of track (see fig. F_02_129)
press (A) button.
If the calibration had been faultless,
there will be a acoustic sign and
Pulse” text will be displayed.
After 3 sec, calibration value will be
displayed on a display
After another 2 sec, calibration is fin-
ished automatically, dashboard is cali-
brated and ready for operation
If Error” / “Out of Range!!!” is dis-
played, it means that the calibration
has not been completed and it is nec-
essary to repeat it.

Table of Contents