1. Introduction
The Laser 95 is an easy to use vented petroleum heater.
It provides considerable quantities of heat, automati-
cally regulates the room temperature, uses very little
fuel and electricity and has options for automatic or
manual operation.
This chapter provides all the information required for
the operation of the Laser heater system. All specified
operating procedures must be carried out in the order
in which they are described.
2. Laser FF 95 heater specifications
Nominal yield
(as applied to petroleum heaters): ~92%
Power consumption:
Ventilator capacity: 2.9/1.9/0.8 cubic metre/min.
Fuel source: external tank
Room volume indication when used as main heating
source: 130 - 440m
3
41
Chapter 2, OPERATION
Low Medium High
Heat yield (W) 3.100 6.300 9.500
Fuel consumption (l/h) 0.38 0.73 1.080
Fuel consumption (g/h) 304 584 864
Ignition Burning