Do you have a question about the Zibro Tectro SRE 703 injection and is the answer not in the manual?
Detailed internal component diagrams for SRE 156, SRE 166, SRE 176, SRE 250, SRE 260.
Lists error codes, their causes, related parts, and checking items.
Steps for front panel, heat chamber, circuit board, cabinet, burner, mat, and igniter.
Steps for fuel pipe, nozzle, pump, thermistor, blower motor, switches, and air duct.
Steps for float switch, fuel sensor, tip-over switch, and air duct.
Steps for high limit switch, fan, power switch, and panel base.
Steps for disassembling SRE 176 front panel, heat chamber, top panel, circuit board, and cabinet.
Steps for SRE 176 burner, fuel system, and blower motor disassembly.
Steps for SRE 176 high limit switch, air duct, fan, power switch, and panel disassembly.
Steps for SRE 250 grille, front panel, cabinet, heat element, and glass cylinder removal.
Steps for SRE 250 secondary flame rod, burner, mat, circuit board, and transformer removal.
Steps for SRE 250 switch, igniter, flame rod, and fuel pipe disassembly.
Steps for SRE 250 fuel nozzle, thermistor, pumps, switch, fan motor, reflector, and limit switch removal.
Steps for SRE 260 grille, front panel, cabinet, heat element, and glass cylinder removal.
Steps for SRE 260 mat, board, transformer, switches, igniter, flame rod, and fuel pipe removal.
Steps for SRE 260 fuel nozzle and burner thermistor removal.
Steps for SRE 260 nozzle, thermistor, pumps, switch, fan motor, reflector, limit switch, power switch, and panel circuit board removal.
Wiring diagrams for the main circuit board of different heater models.
Explains E-0 error related to high limit switch and circulation fan.
Explains F-0 error related to main circuit board soldering.
Explains E-1 error related to room thermistor connection or failure.
Explains F-1 error related to igniter, burner thermistor, or main circuit board.
Explains E-2 error related to flame rod, transformer, or fuel pump.
Explains E-5 error related to tip-over switch actuation or failure.
Explains E-6 error related to incomplete combustion or airflow problems.
Provides further explanations for E-6 error causes like altitude, filter, burner ring, burner mat, and fuel pump.
Explains E-7 error related to high room temperature or thermistor issues.
Explains E-8 error related to blower motor revolution or stoppage.
Explains E-9 error, bar display illumination, and related issues.
Guides through troubleshooting power supply, fuses, fan motor, blower motor, and circuit board.
| Dimensions | 466 x 349 x 445 mm |
|---|---|
| Weight | 13.5 kg |
| Frequency | 50 Hz |
| Thermostat | Yes |
| Heating Area | 28 - 76 m³ |
| Safety Features | Overheat protection, tip-over switch |