MS - SOUND decoders MS440 to MS990 and MN - NON-SOUND decoders MN170 to MN340 Page 81
CV
Denomination
Range
Default
Description
8
#837
Script processes
Bit 0-7
0
Bit 0 - 7 = 1: Deactivate scripts 1 - 8
5.6
#838
Thyristors
Pitch fast
0 255
Pitch at fast speed.
#839
Software Version
0
Decoder Software, second Subversion
8
#843
Script processes
0
Bit 0 - 7 = 1: Deactivate scripts 9 - 16
#844
E-motor sound
max. pitch
= 0: Limitation at value 100 (like MX Sound Decoder)
#980
-
#1019
Script CVs, see
changelog ZSP
0
Values of these CVs are read by scripts. This allows to
change values in scripts when the project is stored in
the decoder.
CVs in higher CV pages
Description
3.25
CV-Page 145/0
(i.e.. CV #31 = 145, CV #32 = 0)
CVs #262 - #277, #281 - #284
For large scale decoder, if more than 4 servos can be operated:
Identical meaning as CV page 0 (main page), CVs #162 - #177
resp. #181 - #184, but for servo control lines 5 to 8 (instead of 1 to
4)
3.22
CV-Page 145/0,
(i.e. CV #31 = 145, CV #32 = 0)
CVs #501, #502, #505
from SW version 5.00 or later
Identical meaning as CV page 0 (main page), CVs #351, #352, #355
(there for fan V1), but fan output V2.