Operating Procedures
Tap Operation
Boiling water
Zip Autoboil is fitted with a two-way tap for filtered instant
boiling water.
For instant boiling water, gently pull the top of the tap
forward.
Boiling water will flow until the tap handle is released.
This operation gives fingertip flow control for safe filling of
cups and mugs.
To fill larger vessels such as teapots and saucepans, rotate
the tap 180 degrees and depress it until it locks into a
horizontal position.
Boiling water will flow until the tap is returned to its normal
vertical position. This operation allows the vessel to be filled
without holding your hand where it may be affected by steam.
1. Turn the lter anti-clockwise.
NOTE: For safe operation, the filter cartridge should be
replaced every 6-12 months, or earlier if you notice a
persistent reduction in water pressure from the appliance
or an unpleasant taste or odour in the water.
To Replace Filter:
Turn the filter anti-clockwise (fig.1) and pull the
cartridge down (fig.2). Have an absorbent cloth ready as
a small amount of water will be released as the filter is
removed. The cartridge should release from the filter
head.
Replace with a new filter by gently pushing up,
engaging the key and turning the filter clockwise until
the filter clicks or locks into place.
Perform filter flush by following the steps 1 - 4 only on
page 8 (Step 7 - Commissioning).
Go to [Replace Fitler] screen to
reset the lter usage
counter. Follow the instructions on page 14 (3.4.3
Replace Filter) section for details of menu operation.
Warning! Not changing filtration cartridges when
required, may cause the water to become biologically
unsafe.
If the Zip Autoboil is switched off for a long period of time
(e.g. More than a weekend), run water through the outlet for
at least 5 minutes before consumption.
Filter Replacement
Fig.1
2. Remove
the lter by
gently pull-
ing down.
Fig.2