Page 9 of 12 Zip Hydroboil - Installation & Operating Instructions - 85264 - May 2013 v1.01
Template Dimensions
38mm
1.5-3.0L
53mm
5.0-7.5L
65mm
Clearance
56mm
POSITIONING PIN
ELECTRICAL WIRING POSITION
COLD INLET POSITION
CONCEALEDVENTPOSITION
72mm
15
25
35mm 42mm
COLD
INLET
VENT
BENCH TOP
38mm
1.5-3.OL
53mm
5.0-7.5L
19mm
20mmClearance
200mmClearance
150mm
Clearance
274mm(1.5&3.0L)
304mm(5.0&7.5L)
318mm1.5L
416mm3.0L
448mm5.0L
561mm7.5L
Warning:Thisappliancemustbeearthed.
Followingremedialservicetheearthingcontinuityoftheheatermustbecheckedby
aqualifiedtechnicianusinganappliancetester,orcontinuitytesterofaccuracyClass
5 or better. Class 5 denotes an accuracy of 5% full scale deflection.
1. Isolatepowersupply.
2. Setmeterto0ohmwithleadsconnectedtogether.
3. Connect one test lead to the earth pin on the three pin plug.
4. Connect the other test lead to a bare patch of metal (preferably on the
edge) of the top of the cover, then to the front cover of the unit, and
then to the tap top under the plastic paddle. This can be achieved by
inserting the probe up from behind the paddle without losing water.
Warning:Thewatermaybeboiling-showextracare.
5. Testthatineveryinstancetheelectricalresistancedoesnotexceed1ohm.
Earthing Continuity Verification & Electrical Diagram
If required, an earth continuity test
canbeperformedbytestingbetween
the earth pin on the products lead and
aexposedpieceofmetalonthecase
and the tap body.