SECTION 6: Set up the ventilation
Models with front vent
The cupboard exhaust must be cut out. It provides a safe exhaust
for refrigerant gas in the unlikely event of a leak.
• Cold air is drawn in through the inlet vent and gap provided by the door
buffers. The inlet vent is positioned in the cupboard side, door or floor.
• Warm air is exhausted through the base of the Command Centre, through
the cupboard floor cut-out.
• Observe 100mm inlet / outlet vent separation.
4mm door buffers
(supplied)
Air inlet cut-out options (refer to the
instructions provided with the vent grilles)
Air exhaust vent cut-out.
Check size relative to your product.
c
c
b
a
b
a
285
60
326
43max
Align the mounting plate to the edge of
the cupboard floor, and secure with the 4
self-tapping screws supplied.
240
40
For Command Centre width 280mm
100mm
Then, secure Command Centre to
mounting plate with 2 screws supplied.