Quick Start Installation Guide
807118UK v1.12 12.23 G5 BC Quick Start Guide
13
SECTION 6: Set up the ventilation
Models with front vent
The cupboard exhaust must be cut out. It provides a safe exhaust
for refrigerant gas in the unlikely event of a leak.
!
!
Cold air is drawn in through the inlet vent and gap provided by the door
buffers. The inlet vent is positioned in the cupboard side, door or floor.
Warm air is exhausted through the base of the Command Centre, through
the cupboard floor cut-out.
Observe 100mm inlet / outlet vent separation.
4mm door buffers
(supplied)
Air inlet cut-out options (refer to the
instructions provided with the vent grilles)
Air exhaust vent cut-out.
Check size relative to your product.
c
c
b
a
b
a
285
60
326
43max
Align the mounting plate to the edge of
the cupboard floor, and secure with the 4
self-tapping screws supplied.
240
40
For Command Centre width 280mm
100mm
Then, secure Command Centre to
mounting plate with 2 screws supplied.